2007
DOI: 10.1016/j.sna.2007.02.004
|View full text |Cite
|
Sign up to set email alerts
|

Environmental monitoring system compliant with the IEEE 1451 standard and featuring a simplified transducer interface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
1

Year Published

2009
2009
2016
2016

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 13 publications
0
8
0
1
Order By: Relevance
“…Several existing serial buses, I 2 C (integrated circuit commonly referred to as "two wire interface"), and SPI (serial peripheral interface), TII (transducer independent interface) have been reviewed for different applications [33]. Bissi et al described the structure of IEEE 1451 standards multiprocessor control system and they also explained the RS232 asynchronous communication between STIM and NCAP [34], [35].…”
Section: Standard Transducer Interface Module (Stim)mentioning
confidence: 99%
“…Several existing serial buses, I 2 C (integrated circuit commonly referred to as "two wire interface"), and SPI (serial peripheral interface), TII (transducer independent interface) have been reviewed for different applications [33]. Bissi et al described the structure of IEEE 1451 standards multiprocessor control system and they also explained the RS232 asynchronous communication between STIM and NCAP [34], [35].…”
Section: Standard Transducer Interface Module (Stim)mentioning
confidence: 99%
“…Kao što je ve pomenuto, podaci se tipi no transportuju od sloja fizi kih ure aja u vidu mernih vrednosti, pa do U okviru inicijative Open Geospatial Consortium -Sensor Web Enablement (OGC-SWE), definisani su servisi i set standardnih interfejsa za pristup senzorskim mrežama i arhivama mernih podataka [4]. Me utim, u ovom slu aju se pristupa podacima koji se ve nalaze u mreži, ali se ne rešava problem njihovog itanja iz fizi kih ure aja i dopremanja do mreže.…”
Section: Uvodunclassified
“…The program flow chart is shown in Figure 2, the AT89S51 works as described in the flow chart, at the beginning, it does an initialization, then checks whether the signal NIOE(pin P1.6) is equal to zero, that is TII interface for either a data transport request or a sensor trigger request from the NCAP [6][7][8][9]. Define abbreviations and acronyms the first time they are used in the text, even after they have been defined in the abstract.…”
Section: Stim Software and Functions Designmentioning
confidence: 99%