1979
DOI: 10.6028/jres.084.011
|View full text |Cite
|
Sign up to set email alerts
|

Enthalpies of solution of Kbr, Ki, Kio3, and Kio4 in H2o

Abstract: Enthalpy of soluti on measureme nt s of four potassium salts in H20 were made in either an adiabatic or an iso pe ribol cal orimeter or both . The following summari zes the measured and recomme nd ed values: The value for KIO. has bee n corrected for the hydrol ys is of the pe ri odate ion. The .:lC " = -(82. 5 ± 4.3)J · mol -I ·K-1 for the unh ydrolysed reaction. For the reaction of KBr in H20 , .:l C " was measured as -(1 66.6 ± 7.2) ]-,nol -I·K -I in the temperature range 298 K to 3 19 K.Measure ments with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1980
1980
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 5 publications
(9 reference statements)
0
5
0
Order By: Relevance
“…Gunn [4] s howed differences of as much as 35 J.mor l (0 .2%) in M ,o)n of samples with different ori gin s and drying procedures. A recent stud y [5] revea led systemati c errors of as much as 0. 7 perce nt in th e enthalp y of solution of KBr measured by three high-precision ca lori meters.…”
Section: Intraductionmentioning
confidence: 99%
“…Gunn [4] s howed differences of as much as 35 J.mor l (0 .2%) in M ,o)n of samples with different ori gin s and drying procedures. A recent stud y [5] revea led systemati c errors of as much as 0. 7 perce nt in th e enthalp y of solution of KBr measured by three high-precision ca lori meters.…”
Section: Intraductionmentioning
confidence: 99%
“…In our earlier study on KBr [5] the isoperibol results of Efimov showed a puzzling curvature in the plot of the values for the enthalpy of solution of KBr versus concentration of the final solutions. It now appears that this was due to a comb ination of errors from thermal lags and inadequate stirring.…”
Section: Recommended Procedures For Calorimeters Requiringmentioning
confidence: 99%
“…The vessel temperature was constantly rising throughout the experiment, and the mean temperature of the initial and final calibration periods differed from that of the reaction period by about 0.1 K or less (one exception was 0.3 K). The observed temperature 5 The results in section 4 indicate a sys temati c error estimated to be 0.06 percent du e to failure to me asure the e nergy equi va le nts over th e sam e tempe rature range as th e reacti o n. This would in crease th e mean valu e by 0.01 kj .mo!-I which would still he within th e experimental un ce rtaint y of th e valu e obtained from meas urements in th e adiabatic calorimete r.…”
Section: Addition Of Electrical Energy During Endothermic Reactionsmentioning
confidence: 99%
See 2 more Smart Citations