2007
DOI: 10.1007/s00604-007-0761-8
|View full text |Cite
|
Sign up to set email alerts
|

Enrichment and flame atomic absorption spectrometric determination of palladium using chelating matrices designed by functionalizing Amberlite XAD-2/16 and silica gel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2008
2008
2012
2012

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…New Au values in GBW(E)070013 and the soil GBW07405 were reported by Liu and Liang (2007). The geological RM GBW07293 and the auto catalyst NIST SRM 2557 were used by Venkatesh and Singh (2007) to demons-trate the validity and accuracy of their Pd determination. In order to establish the validity of their method for the determination of Au, Pd, Ag and other elements, Hang et al (2007) used the Pt-Pd ore RM GBW07293.…”
Section: Reference Materials For Platinum-group Elementsmentioning
confidence: 99%
“…New Au values in GBW(E)070013 and the soil GBW07405 were reported by Liu and Liang (2007). The geological RM GBW07293 and the auto catalyst NIST SRM 2557 were used by Venkatesh and Singh (2007) to demons-trate the validity and accuracy of their Pd determination. In order to establish the validity of their method for the determination of Au, Pd, Ag and other elements, Hang et al (2007) used the Pt-Pd ore RM GBW07293.…”
Section: Reference Materials For Platinum-group Elementsmentioning
confidence: 99%
“…Six chelating matrices prepared by functionalizing Amberlite XAD-2 and XAD-16 and silica gel were studied as a sorbent for enrichment of Pd [191]. Amberlite XAD-2 and XAD-16 were anchored with 2,3-dihydroxypyridine (DHP) (I and II), Amberlite XAD-2 and XAD-16 were anchored with 2-{[1-(3,4-dihydroxyphenyl)-methylidene]amino}benzoic acid (DMABA) (III and IV), and silica gel was anchored with 3,4-dihydroxybenzaldehyde (DHB) and iminodiacetic acid (IDA) (V and VI).…”
Section: Functionalized Materialsmentioning
confidence: 99%
“…Since the levels of palladium in geological and environmental samples are low, a preconcentrative separation of palladium(II) from other noble and transition elements is essential prior to the determination by simple, reliable, and readily available FAAS 19 or ICP‐MS 20. The SPE system is one of the widely used and fast emerging preconcentrative separation techniques because of its several advantages 21. Recently, SPE techniques for the preconcentration of traces of heavy metal ions have become increasingly popular, especially compared to the traditional solvent extraction methods, because of its simplicity, application speed, a relatively high concentration factor, and ability of treating large volume samples 22, 23.…”
Section: Introductionmentioning
confidence: 99%