2018
DOI: 10.3103/s0027131418030070
|View full text |Cite
|
Sign up to set email alerts
|

Enhancement of the Sensitivity of a Lateral Flow Immunoassay by Using the Biotin–Streptavidin System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…A PCT assay utilizing a biotin–streptavidin system enhanced transverse flow immunoassay. The amplification of the analysis signal resulted from the accumulation of AuNP clumps [ 101 ]. Another platinum staining method based on a test strip retained the original properties of colloidal gold while leveraging platinum nanoparticles (PTNPs) with good catalytic activity as a signal label, achieving sensitive and quantitative testing [ 102 ].…”
Section: Immune Colloidal Gold Technique For Pct Detectionmentioning
confidence: 99%
“…A PCT assay utilizing a biotin–streptavidin system enhanced transverse flow immunoassay. The amplification of the analysis signal resulted from the accumulation of AuNP clumps [ 101 ]. Another platinum staining method based on a test strip retained the original properties of colloidal gold while leveraging platinum nanoparticles (PTNPs) with good catalytic activity as a signal label, achieving sensitive and quantitative testing [ 102 ].…”
Section: Immune Colloidal Gold Technique For Pct Detectionmentioning
confidence: 99%
“…The successful functionalization of the nanoparticles with neutravidin was confirmed by testing them against the biotin printed across the membrane as the test line. Streptavidin molecules have four binding sites with an extraordinary affinity for biotin [52,53]. Therefore, when neutravidin is on the nanoparticle surface, the complex formed will become trapped in the biotin line.…”
Section: Biosensing Applicationmentioning
confidence: 99%
“…The combination of the specificity and sensitivity in the detection method could lead to the multi-stage amplification of biological signals (Meyer, Sauerwein, & Mutayoba, 1990;Sai et al, 2010). Streptavidin-biotin system also used to combine with materials like nanoparticles in flow immunoassay (Serebrennikova, Samsonova, & Osipov, 2018), immunomagnetic beads (Ming et al, 2018;Shan et al, 2014) and sandwich immunosensor (Zhang et al, 2018) to improve the specificity and sensitivity of the detection methods.…”
Section: Specificitymentioning
confidence: 99%