2005
DOI: 10.1016/j.sna.2004.11.017
|View full text |Cite
|
Sign up to set email alerts
|

Enhancement of synthetic jets by means of an integrated valve-less pump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
39
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 50 publications
(40 citation statements)
references
References 22 publications
1
39
0
Order By: Relevance
“…Kinsler et al [55]. Following derivation described in [56], the first natural frequency of the present actuator generating SJ can be derived as (2) where c is the shape constant of the diaphragm deflection volume (from 0.5 for paraboloid to 1 for cylinder), A is the cross-sectional area of the actuator orifice (A = B × 40 mm), A D is the area of the diaphragm (A D = πD D 2 / 4), and ρ is the fluid (water) density, while K P was evaluated by an auxiliary experiment and used recently [42] for the present diaphragms as K P = 2.9 × 10 6 N/m 3 . For the present geometry ( Figure 1) and parameters (ρ = 997 kg/m 3 , c = 0.5), Eq.…”
Section: Resultsmentioning
confidence: 99%
“…Kinsler et al [55]. Following derivation described in [56], the first natural frequency of the present actuator generating SJ can be derived as (2) where c is the shape constant of the diaphragm deflection volume (from 0.5 for paraboloid to 1 for cylinder), A is the cross-sectional area of the actuator orifice (A = B × 40 mm), A D is the area of the diaphragm (A D = πD D 2 / 4), and ρ is the fluid (water) density, while K P was evaluated by an auxiliary experiment and used recently [42] for the present diaphragms as K P = 2.9 × 10 6 N/m 3 . For the present geometry ( Figure 1) and parameters (ρ = 997 kg/m 3 , c = 0.5), Eq.…”
Section: Resultsmentioning
confidence: 99%
“…Following the previous experience with SJ actuators (Trávníček et al [8][9][10][11][12]), the full scale axial fan was equipped by electrodynamically driven SJ actuators, located at the IGVs. Namely three SJ actuators were built in the fan casing near the IGVs at the expected separation points.…”
Section: Synthetic Jet Actuators and Experimental Methodsmentioning
confidence: 99%
“…Figure 3 shows that the maxima of the velocity are found at 600 Hz for both variants, which are approximately 32 m/s and 38 m/s, respectively. These maxima are relevant to the first resonance of the actuator resulting from the mechanical energy transformation -namely the kinetic energy of the fluid column and the potential energy of the diaphragm are mutually transformed [8]. Finally, the frequency (600 -700) Hz was chosen as the operating frequency range.…”
Section: Efm 2012mentioning
confidence: 99%
“…This method has been also applied to SJ actuator design: two actuator cavities separated by a common diaphragm, so that they operate in the antiphase -see, e.g., Lee and Goldstein (2002), TrávníĀek et al(2004, 2005aand 2005b, and more recently Luo et al (2006).…”
Section: Regular Papermentioning
confidence: 99%
“…The "hybrid synthetic jet" (HSJ) combines the ZNMF jet and a fluidic pumping by a valve-less pump -as described in previous publications by TrávníĀek et al (2005aTrávníĀek et al ( , 2005bTrávníĀek et al ( and 2006, and Chen et al (2006). In contrast to the standard SJ, the HSJ is an intrinsically non-zero-net-mass-flux jet.…”
Section: Introductionmentioning
confidence: 99%