2015
DOI: 10.1051/ijmqe/2015014
|View full text |Cite
|
Sign up to set email alerts
|

Enhancement of AC high voltage measurements’ uncertainty using a high voltage divider calibration method

Abstract: Abstract. This paper discusses enhancing of the measurements' uncertainty for AC high voltage up to 100 kV. This is achieved by using a high voltage divider calibration method. Voltage measurements have been carried out at the Egyptian national institute for standards (NIS), using a high voltage measuring system (Phenix-KVM100), that consists of a high voltage divider and a voltage display. The voltage divider and display have been calibrated in low and high voltage ranges. Reference standard digital voltmeter… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…However, their impacts on the uncertainty budget are insignificant compared to the dominant factors used in this work. 4,9 Tables 5 and 6 show the uncertainty budgets for the 200 kV DC and AC calibrations, respectively.…”
Section: Calibration Of the 200 Kv High Voltage Systemmentioning
confidence: 99%
See 3 more Smart Citations
“…However, their impacts on the uncertainty budget are insignificant compared to the dominant factors used in this work. 4,9 Tables 5 and 6 show the uncertainty budgets for the 200 kV DC and AC calibrations, respectively.…”
Section: Calibration Of the 200 Kv High Voltage Systemmentioning
confidence: 99%
“…However, their impacts on the uncertainty budget are insignificant compared to the dominant factors used in this work. 4,9 Tables 5 and 6 show the uncertainty budgets for the 200 kV DC and AC calibrations, respectively. The final calibration results of the 200 kV system with their expanded uncertainties in both volts and percentages for the DC and AC modes are listed in Tables 7 and 8, respectively.…”
Section: R E T R a C T E Dmentioning
confidence: 99%
See 2 more Smart Citations
“…The last setup is calibrating a 200 kV AC high voltage measuring system by means of the two calibrated capacitors according to IEC 60060-2:2010 international standard [73]. AC High voltage source is utilized to supply the high voltage side in all calibration setups [74,75].…”
Section: Innovative Experimental Measuring Technique For High Voltage...mentioning
confidence: 99%