2006
DOI: 10.1016/j.jhazmat.2005.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced reduction of perchlorate by elemental iron at elevated temperatures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0
1

Year Published

2007
2007
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 41 publications
(10 citation statements)
references
References 16 publications
(18 reference statements)
0
9
0
1
Order By: Relevance
“…These improved k SA values suggest that stabilizers not only increased the surface area of the nanoparticles (because of the much smaller particle size), but also resulted in a more reactive particle surface. On the other hand, the k SA value for CMCstabilized ZVI nanoparticles is more than two orders of magnitude greater than that for a cast iron (surface area-1.29 m 2 g À1 ) reported by Oh et al (2006a).…”
Section: 3mentioning
confidence: 58%
See 1 more Smart Citation
“…These improved k SA values suggest that stabilizers not only increased the surface area of the nanoparticles (because of the much smaller particle size), but also resulted in a more reactive particle surface. On the other hand, the k SA value for CMCstabilized ZVI nanoparticles is more than two orders of magnitude greater than that for a cast iron (surface area-1.29 m 2 g À1 ) reported by Oh et al (2006a).…”
Section: 3mentioning
confidence: 58%
“…Oh et al (2006a) reported that 98% of perchlorate in water was reduced by cast iron (surface area ¼ 1.29 m 2 g…”
mentioning
confidence: 99%
“…Chemical treatment processes (e.g., chemical reduction with iron metal) are typically sluggish (Moore et al, 2003). However, recent studies demonstrate high reduction rates of ClO 4 − with iron metal at elevated temperatures (200°C) (Oh et al, 2006) or with nano‐scale iron (Cao et al, 2005). Nevertheless, it is currently impractical to apply these latest developments to in situ or ex situ drinking water treatment systems.…”
mentioning
confidence: 99%
“…하지만 우리나라의 경우 는 6.25 전쟁과 perchlorate 관련 산업이 급속한 발전을 거치면서 perchlorate의 높은 오염 가능성에도 불구하고 매우 제한적으로 perchlorate 오염조사가 실시되었다 (13)(14)(15). 또한, 현재까지 국내의 perchlorate 관련 연구는 전국적인 오염실태와 사람이 섭취하는 주 요 음식물에서의 오염 정도 등에 대한 체계적 연구가 이루어지 지 않은 상태에서 제거 관련 연구만 제한적으로 실시되었다 (16)(17)(18). 최근 국외에서는 다양한 환경시료를 대상으로 최적의 perchlorate 분석을 위한 전처리 방법 및 기기분석연구가 활발히 진행되어 왔 다. Perchlorate 측정방법에는 중량 측정법(gravimetry), 분광측정법 (spectrophotometry), 전기화학법(electrochemistry), 모세관 전기영동 법(capillary electrophoresis) 등 많은 종류의 측정방법이 있으나 사 용의 용이성, 낮은 검출한계, perchlorate의 선택성 등이 우수한 이온 크로마토그래피 방법을 주로 사용하고 있다.…”
Section: CLunclassified