2018
DOI: 10.1016/j.snb.2017.08.114
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced performance of label-free electrochemical immunosensor for carbohydrate antigen 15-3 based on catalytic activity of cobalt sulfide/graphene nanocomposite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
29
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 71 publications
(29 citation statements)
references
References 36 publications
0
29
0
Order By: Relevance
“…The developed immunosensor showed a wide linear range of 0.1-150 U mL −1 and a low detection limit of 0.03 U mL −1 . The immunosensor demonstrated good precision, reliability, specificity and was successfully applied in serum samples for CA15-3 detection [12].…”
Section: Cancer Antigen 15-3 (Ca15-3)mentioning
confidence: 98%
“…The developed immunosensor showed a wide linear range of 0.1-150 U mL −1 and a low detection limit of 0.03 U mL −1 . The immunosensor demonstrated good precision, reliability, specificity and was successfully applied in serum samples for CA15-3 detection [12].…”
Section: Cancer Antigen 15-3 (Ca15-3)mentioning
confidence: 98%
“…The electrochemical immunosensor was employed to detect CYFRA21-1 and exhibited a wide linear range of 0.25-800 ng/mL and low detection limit of 100 pg/mL. Other nanoparticles as cobalt sulfide [669] (detection of CA15-3 antigen in wide linear range of 0.1-150 U mL −1 and a low detection limit of 0.03 U mL −1 ), Pd [670] (prostate-specific antigen with sensitivity 28.96 µA mL ng −1 cm −2 corresponding to 10 pg mL −1 ), oxides as ZrO 2 [671] (CYFRA-21-1 biomarker with sensitivity 0.756 µA mL ng −1 and a remarkable lower detection limit of 0.122 ng mL −1 ), Fe 3 O 4 [672] (detection of prostate specific antigen or prostate specific membrane antigen with excellent LOD of 15 fg/mL for PSA and 4.8 fg/mL for PSMA were achieved in serum).…”
Section: Figure 38mentioning
confidence: 99%
“…They detected four proteins—CA-125, neuron-specific enolase (NSE), fragment antigen 21-1 (Cyfra21-1), and squamous cell carcinoma antigen (SCCA) at 0.0054 U mL −1 , 2.3 pg mL −1 , 5.5 pg mL −1 , and 4.8 pg mL −1 , respectively, using amperometric detection [ 122 ] ( Figure 9 ). Many other works, in label-free protein detection, have attained clinically-relevant detection limits, but they have only detected single biomarkers and improvements are required for multiplexing [ 123 , 124 , 125 , 126 ].…”
Section: Immunoassay Techniques For Printed Electrodesmentioning
confidence: 99%