2015
DOI: 10.1109/tpwrd.2013.2294651
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced Equivalent Model of the Modular Multilevel Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
33
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 91 publications
(33 citation statements)
references
References 11 publications
0
33
0
Order By: Relevance
“…1 shows the three-terminal HVDC system considered. All converter stations are modeled as HBMMCs using modified average models [7][8][9]23]. The system parameters are listed in Table I.…”
Section: Consideration Of DC Fault-tolerant Operationmentioning
confidence: 99%
See 1 more Smart Citation
“…1 shows the three-terminal HVDC system considered. All converter stations are modeled as HBMMCs using modified average models [7][8][9]23]. The system parameters are listed in Table I.…”
Section: Consideration Of DC Fault-tolerant Operationmentioning
confidence: 99%
“…The losses introduced by short-circuit currents expose the diodes to thermal stresses and are usually measured by the integral of the surge current I 2 t. ABB, Infineon and Dynex provide IGBT and the anti-parallel diode with 3.3kV voltage rating and their diode I 2 t are 911kA 2 s, 730kA 2 s and 720kA 2 s respectively [4]. Bypass elements, typically thyristors, are used to protect the freewheeling diodes of the HB sub-modules (SMs) in MMC [5][6][7][8][9]. However, prolonged system outage still occurs.…”
mentioning
confidence: 99%
“…Compared to the average model with only one equivalent capacitance, the modified average model in Fig. 3 reproduces MMC behavior during dc fault ride-through operation.model derivation and switching logic is represented in [18], [19] and [20]. …”
Section: Revised Generic MMC Average Modelmentioning
confidence: 99%
“…To reduce model complexity, the SM number per arm N is reduced and chosen as 24 with half-bridge (HB) SMs operating at 50 kV. In typical applications, hundreds of submodules with voltage rating of several kilovolts are required, however from a simulation perspective, assuming the adopted model with reduced SMs accelerates simulation time but does not significantly affect the quality of the outcome [6,16,19].…”
Section: A Power Lossesmentioning
confidence: 99%
“…Each SM in the tested model represents several tens of series-connected SMs of a practical implementation [19]. The parameters of the IGBTs and diodes are thus required to be set according to the equivalent series-connected circuit.…”
Section: A Power Lossesmentioning
confidence: 99%