Engineering precision relocation capability into a large-cantilevered telescoping diagnostic for a Kirkpatrick Baez x-ray Optic

Abstract: The Kirkpatrick Baez Optic (KBO) diagnostic designed for the National Ignition Facility (NIF) requires very precise alignment between four pairs of mirrors that make up four x-ray imaging channels. Furthermore, the overlapping image axis of the four pairs must be aligned to within a 50 µm radius of the NIF target center. In order to achieve this the diagnostic utilizes a telescoping snout that when extended, locates the mirrors at the end of a Diagnostic Load Package (DLP), cantilevered more than three meters … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 11 publications
(4 reference statements)
0
2
0
Order By: Relevance
“…To reduce the noise, the design of the imaging path will be optimzed in the next KB microscope. It is suggested to adopt a crossing aperture in the imaging path as that in reference [11,12] and enclose the mirrors module and the imaging module in a sealed tube. The calibration of the reflectivity and spatial resolution will be also implemented.…”
Section: Similarity Check Of the Images In Different Imaging Channelsmentioning
confidence: 99%
See 1 more Smart Citation
“…To reduce the noise, the design of the imaging path will be optimzed in the next KB microscope. It is suggested to adopt a crossing aperture in the imaging path as that in reference [11,12] and enclose the mirrors module and the imaging module in a sealed tube. The calibration of the reflectivity and spatial resolution will be also implemented.…”
Section: Similarity Check Of the Images In Different Imaging Channelsmentioning
confidence: 99%
“…And it is easy to be couple to a multi-chips time gated X-ray detector, to realize the time-resolved high resolution imaging. NIF has built some 4-channels KB microscopes [1,[11][12][13] for the hot spot diagnostics and the hydrodynamic instability growth radiography. A novel 16-channels KB microscope was designed and built on OMEGA [14][15][16], which was also already coupled to the time gated X-ray detector.…”
Section: Introductionmentioning
confidence: 99%