Energy subtraction computed tomography measured by current-mode detector

Abstract: For the reduction of exposure dose in contrast media detection with x-ray transmission measurements, the energy measurement of x-rays and the energy subtraction (ES) method have been shown to be effective. To make the ES method applicable, a novel detector for unfolding the x-ray energy distribution was proposed by the authors. As an application of this novel detector, a CT image was reconstructed with ES data and compared with the image reconstructed using electric current data.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2009
2009
2013
2013

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 6 publications
(9 reference statements)
0
3
0
Order By: Relevance
“…4) Although the CT values in the iodine contrast region of the phantom were larger than the ones obtained by a conventional current measurement CT, the CT values in the homogeneous acrylic region were dependent on the thickness of acrylic through which the X-rays passed before interacting with the detector. This defect was the result of an insufficient unfolding method, because the CT values in the acrylic region were constant when the energy of each X-ray was measured as shown in Fig.…”
Section: Introductionmentioning
confidence: 79%
See 1 more Smart Citation
“…4) Although the CT values in the iodine contrast region of the phantom were larger than the ones obtained by a conventional current measurement CT, the CT values in the homogeneous acrylic region were dependent on the thickness of acrylic through which the X-rays passed before interacting with the detector. This defect was the result of an insufficient unfolding method, because the CT values in the acrylic region were constant when the energy of each X-ray was measured as shown in Fig.…”
Section: Introductionmentioning
confidence: 79%
“…4) This indicates that response functions as a function of X-ray path length are necessary for the unfolding process. We describe the method of obtaining response functions as a function of X-ray path length for CT measurements in the following section.…”
Section: Brief Description Of the Transxend Detectormentioning
confidence: 99%
“…Initial studies that compared energy subtraction CT and conventional current measurement CT on a simple phantom, using the transXend detector, have been reported elsewhere. 11) …”
Section: Discussionmentioning
confidence: 99%