Energy management of traction power substations on the Dallas Area Rapid Transit system

Abstract: The Dallas Area Rapid Transit (DART) Light Rail System (LRT) is unique among all other Light Rail Transit Systems in North America because it employs a real time, Energy Management Demand Metering System (EMS) to monitor and control traction power load.This system has been provided to reduce the cost impacts of demand billing imposed by the local electric utility. The fundamental requirement of the EMS is to predict the occurrence and timing of maximum peak loads and remotely control the power contributions fr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0
2

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
1
0
2
Order By: Relevance
“…In addition, there are some traction systems whose substations are directly connected to the local electric utility company network and, therefore, those substations are subjected to demand billing. In those cases, higher the contracted demand, higher the costs [9]. An optimal load sharing would better distribute the total demand among the traction substations and also would reduce the peak demand on heavier loaded substations.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, there are some traction systems whose substations are directly connected to the local electric utility company network and, therefore, those substations are subjected to demand billing. In those cases, higher the contracted demand, higher the costs [9]. An optimal load sharing would better distribute the total demand among the traction substations and also would reduce the peak demand on heavier loaded substations.…”
Section: Introductionmentioning
confidence: 99%
“…A carga em uma subestação, em um certo período de tempo e para um dado headway, pode se aproximar ou exceder a demanda contratada. Para minimizar o impacto desta demanda, as contribuições das subestações podem ser redistribuídas,direcionando a carga excedente para as subestações que não estejam na condição de demanda máxima (load shifting) (Griffiths;Sanders, 1999).…”
Section: A6 Retificadores Controladosunclassified
“…Um exemplo de aplicação é o sistema de VLTs pertencente ao DART (Dallas Area Rapit Transit) nos Estados Unidos (Flowers, 1995) e (Griffiths;Sanders, 1999).…”
Section: A6 Retificadores Controladosunclassified