2021 IEEE Global Communications Conference (GLOBECOM) 2021
DOI: 10.1109/globecom46510.2021.9685613
|View full text |Cite
|
Sign up to set email alerts
|

Energy Efficient Data Recovery from Corrupted LoRa Frames

Abstract: High frame-corruption is widely observed in Long Range Wide Area Networks (LoRaWAN) due to the coexistence with other networks in ISM bands and an Aloha-like MAC layer. LoRa's Forward Error Correction (FEC) mechanism is often insufficient to retrieve corrupted data. In fact, reallife measurements show that at least one-fourth of received transmissions are corrupted. When more frames are dropped, LoRa nodes usually switch over to higher spreading factors (SF), thus increasing transmission times and increasing t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…Throughout our experiments we reported an FDR of 0. In contrast, ReDCoS reports an FDR of 0.13% for š‘˜ = 10 and š‘” = 8 and 0.11% for š‘˜ = 20 and š‘” = 4 [11], i.e., more than 0.1% of decoded payloads of ReDCoS are falsely decoded. Finding the Optimum Point.…”
Section: Analysis Of DCmentioning
confidence: 93%
See 2 more Smart Citations
“…Throughout our experiments we reported an FDR of 0. In contrast, ReDCoS reports an FDR of 0.13% for š‘˜ = 10 and š‘” = 8 and 0.11% for š‘˜ = 20 and š‘” = 4 [11], i.e., more than 0.1% of decoded payloads of ReDCoS are falsely decoded. Finding the Optimum Point.…”
Section: Analysis Of DCmentioning
confidence: 93%
“…However, the vast majority of their frames, i.e., 95%, were transmitted on SF12. Although the above would necessitate the adoption of erasure coding mechanisms, Rahmadhani et al [10], and Yazdani et al [11] showed considerable amounts of received frames ending up corrupted. Specifically, they reported frame corruption of 32% and 50% in SF8, using multiple GWs and single-GW, respectively.…”
Section: A Frame Corruption In Lorawanmentioning
confidence: 99%
See 1 more Smart Citation
“…To ensure security, an ā€œadvanced encryption standardā€ is used. The spreading factor, bandwidth, and coding rate are the key physical layer parameters that influence LoRaā€™s coverage and power consumption, which are described in the following [ 110 , 111 ].…”
Section: Proposed Ism Architecture Using Lora Technologymentioning
confidence: 99%
“…In addition, we believe that both data recovery and improved reception rates are parallel and effective means of improving communication stability. Yazdani et al [11] proposed a method to recover LoRa data efficiently, which helped to improve data integrity, but the recoverability of the data was unstable, and receiving the data as completely as possible in complex environments is a prerequisite for recovering the data.…”
Section: Introductionmentioning
confidence: 99%