2013
DOI: 10.1117/1.jbo.18.8.086005
|View full text |Cite
|
Sign up to set email alerts
|

Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror

Abstract: A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8  mm2 mirror plate and a 1.6×1.4  mm2 device footprint. The diameter of the endoscopic probe is only 3.5 mm. The imaging rate of the SS-OCT system is 50  frames/s. OCT images of both human suspicious oral leukoplak… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
36
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 38 publications
(36 citation statements)
references
References 22 publications
(19 reference statements)
0
36
0
Order By: Relevance
“…Eight of 27 articles described OCT images of different types of oral lesions. Tsai et al analyzed four groups of buccal mucosa samples: healthy mucosa, epithelial hyperplasia, moderate dysplasia, and squamous cell carcinoma of the oral cavity (OSCC), combining the results obtained using their handmade SS‐OCT system with histology.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Eight of 27 articles described OCT images of different types of oral lesions. Tsai et al analyzed four groups of buccal mucosa samples: healthy mucosa, epithelial hyperplasia, moderate dysplasia, and squamous cell carcinoma of the oral cavity (OSCC), combining the results obtained using their handmade SS‐OCT system with histology.…”
Section: Resultsmentioning
confidence: 99%
“…Wang et al combined microelectromechanical systems (MEMSs) with SS‐OCT, creating a mirror‐based MEMS handmade endoscopic OCT. The OCT images of both human oral leucoplakia tissue and normal buccal mucosa were taken in vivo and compared with the histopathological analysis.…”
Section: Resultsmentioning
confidence: 99%
“…However, the reconstructed OCT images may be distorted. The diameter of the fabricated MEMS probe is 3.5mm [15]. The probe body is made of stainless steel for biocompatibility and robustness.…”
Section: Endoscopic Oct Based On 2-axis Scanning Mems Mirrorsmentioning
confidence: 99%
“…Unlike other single fiber endoscope technologies, including distal mirror scanning [2,3], resonant fiber scanning [4], and endoscopic optical coherent tomography [5,6], SEE probes do not require rapid distal scanning, allowing for flexible submillimeter-diameter probes that do not contain moving parts. Interferometric SEE has been shown capable of 3D [7], subsurface [8], and Doppler [9] imaging with a high number of resolvable points and high signal-to-noise ratios (SNRs).…”
mentioning