2005
DOI: 10.1007/s10016-005-0022-4
|View full text |Cite
|
Sign up to set email alerts
|

Endoleak and Endotension Following Open Abdominal Aortic Aneurysm Repair: A Report of Two Cases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…18 According to the report by Arya and colleagues, seroma, which is probably caused by fibroblast ingestion, ultrafiltration, and/or bacterial biofilm infection, cannot be avoided only by aspiration, fenestration, or resection. 19 As mentioned above, we first demonstrated increased intrasac pressure in the absence of endoleak in dogs, for which EVAR was performed using PTFE or Dacron (Coknit) graft with high porosity. Despite an increase in intrasac pressure with Dacron graft, endoleak was not detected by angiography and contrast CT. 2 Although graft material has been postulated to be responsible for the local production and transmigration of serous fluid and sac hygroma after EVAR and open AAA surgery, the relationship between the material of graft or prosthesis and the incidence of aneurysm sac enlargement remains unclear.…”
Section: Etiologymentioning
confidence: 80%
See 1 more Smart Citation
“…18 According to the report by Arya and colleagues, seroma, which is probably caused by fibroblast ingestion, ultrafiltration, and/or bacterial biofilm infection, cannot be avoided only by aspiration, fenestration, or resection. 19 As mentioned above, we first demonstrated increased intrasac pressure in the absence of endoleak in dogs, for which EVAR was performed using PTFE or Dacron (Coknit) graft with high porosity. Despite an increase in intrasac pressure with Dacron graft, endoleak was not detected by angiography and contrast CT. 2 Although graft material has been postulated to be responsible for the local production and transmigration of serous fluid and sac hygroma after EVAR and open AAA surgery, the relationship between the material of graft or prosthesis and the incidence of aneurysm sac enlargement remains unclear.…”
Section: Etiologymentioning
confidence: 80%
“…There are several mechanisms by which pressure can be transmitted to the aneurysm sac. [6][7][8][9][10][11][12][13][14][15][16][17][18][19] The transmission of pressure from the aorta to the aneurysm sac can occur via thrombus layered between the aortic wall and the stent-graft (Table 1). The pressure may also be transmitted through the graft wall.…”
Section: Etiologymentioning
confidence: 99%
“…[8][9][10][11][12] Only 2 cases of a PGS after Dacron graft aortic repair have been reported. 5,14 In the current study, all 20 patients with seromas had PTFE reconstructions. This did not reach significance on univariate analysis due probably to type II statistical error.…”
Section: Discussionmentioning
confidence: 98%
“…Type II endoleaks are the most common endoleaks encountered in clinical practice, accounting for approximately 40% of all endoleaks [9]. They occur when there is retrograde flow of blood into the aneurysm sac via an excluded aortic branch, most commonly the inferior mesenteric artery or a lumbar artery.…”
Section: Discussionmentioning
confidence: 99%
“…They occur when there is retrograde flow of blood into the aneurysm sac via an excluded aortic branch, most commonly the inferior mesenteric artery or a lumbar artery. Many type II endoleaks close spontaneously over time [9]. However, data suggest that patients with a persistent type II endoleak (>6 months) should be considered for more frequent follow-up and/or a more aggressive approach to reintervention [10].…”
Section: Discussionmentioning
confidence: 99%