2020
DOI: 10.1002/ajoc.202000272
|View full text |Cite
|
Sign up to set email alerts
|

Enantioselective Construction of Vicinal Sulfur‐functionalized Quaternary and Tertiary Stereocenters via Organocatalytic Michael Addition of 5H‐Thiazol‐4‐ones to 1‐Azadienes

Abstract: An organocatalytic enantioselective Michael addition of 5H‐thiazol‐4‐ones to 1‐azadienes has been developed. In the presence of chiral phosphoric acid, a series of optically active benzofuran derivatives featured by vicinal sulfur‐containing quaternary and tertiary stereocenters were obtained in high yields (71‐99%) with high stereoselectivities (70–96% ee and 8 : 1–20 : 1 d.r.).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 38 publications
(17 reference statements)
0
12
0
Order By: Relevance
“…1 H NMR spectra were measured with Bruker Ascend 400 MHz spectrometer; chemical shifts were reported in δ (ppm) units relative to tetramethylsilane (TMS) as internal standard. 13 C NMR spectra were measured at 100 MHz with 400 MHz spectrometer; chemical shifts were reported in ppm relative to tetramethylsilane and referenced to solvent peak (CDCl 3 , δ C = 77.00). High-resolution mass spectra (Electron spray ionization) were measured with an Agilent 6520 Accurate-Mass Q-TOF MS system equipped with an electrospray ionization (ESI) source.…”
Section: General Informationmentioning
confidence: 99%
See 4 more Smart Citations
“…1 H NMR spectra were measured with Bruker Ascend 400 MHz spectrometer; chemical shifts were reported in δ (ppm) units relative to tetramethylsilane (TMS) as internal standard. 13 C NMR spectra were measured at 100 MHz with 400 MHz spectrometer; chemical shifts were reported in ppm relative to tetramethylsilane and referenced to solvent peak (CDCl 3 , δ C = 77.00). High-resolution mass spectra (Electron spray ionization) were measured with an Agilent 6520 Accurate-Mass Q-TOF MS system equipped with an electrospray ionization (ESI) source.…”
Section: General Informationmentioning
confidence: 99%
“…Enantiomeric excesses were determined by chiral HPLC analysis using an Agilent 1200 LC instrument with a Daicel Chiralpak IA, IC, or ADH column. 1 H and 13 C NMR spectra for newly synthesized compounds, X-ray single crystal data for product 3ja and copies of the HPLC chromatograms can be found in the Supplementary Materials.…”
Section: General Informationmentioning
confidence: 99%
See 3 more Smart Citations