2017
DOI: 10.1016/j.buildenv.2017.05.011
|View full text |Cite
|
Sign up to set email alerts
|

Empirical analysis of indoor air quality enhancement potential in a liquid-desiccant assisted air conditioning system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 35 publications
(15 citation statements)
references
References 11 publications
0
14
0
Order By: Relevance
“…Simulations were conducted based on the data verified in the previous experimental study. It was indicated in the open literature [8] that the packed tower-type LD dehumidifier could remove 48% of 2.5-5.0 µm particles, and 85% of 10-25 µm particles by using the particle counter, which can measure the number of small airborne particles with the residual error of 0.1%. Consequently, in this work, the PM 2.5 and PM 10 removal rates for the packed-tower-type LD dehumidifier that was used in the DEVap system and LD-IDECOAS were set as 48% and 85%, respectively.…”
Section: Particle Removal Ratesmentioning
confidence: 99%
See 3 more Smart Citations
“…Simulations were conducted based on the data verified in the previous experimental study. It was indicated in the open literature [8] that the packed tower-type LD dehumidifier could remove 48% of 2.5-5.0 µm particles, and 85% of 10-25 µm particles by using the particle counter, which can measure the number of small airborne particles with the residual error of 0.1%. Consequently, in this work, the PM 2.5 and PM 10 removal rates for the packed-tower-type LD dehumidifier that was used in the DEVap system and LD-IDECOAS were set as 48% and 85%, respectively.…”
Section: Particle Removal Ratesmentioning
confidence: 99%
“…This system is a once-through system that serves the zone by supplying conditioned outdoor air, and the zone return air is exhausted to the outside via the indirect evaporative cooler. No cross-contamination occurs, because the zone return air is not redirected to and mixed with the supply air stream [6,8]. The energy benefit of the LD-IDECOAS compared with the conventional VAV system was also indicated in the open literature [9][10][11].…”
Section: Introductionmentioning
confidence: 97%
See 2 more Smart Citations
“…Due the appealing properties of desiccants with their affinity for more than water vapor, such as microorganisms, they are widely used in the applications in which air borne microorganisms could cause major issues, for example hospitals and medical facilities [31][32][33].…”
Section: Figurementioning
confidence: 99%