2000
DOI: 10.1016/s0584-8547(00)00197-x
|View full text |Cite
|
Sign up to set email alerts
|

Elimination of boron memory effect in inductively coupled plasma-mass spectrometry by ammonia gas injection into the spray chamber during analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
59
0
3

Year Published

2000
2000
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(62 citation statements)
references
References 5 publications
0
59
0
3
Order By: Relevance
“…3 mL min −1 (AlAmmar et al, 2000;Foster, 2008). The addition of ammonia gas to the spray chamber ensures that the analyte remains alkaline, which prevents volatile boron from recondensing in the chamber during analysis (Al-Ammar et al, 2000). The measured B isotope signal of the rinse blank was then subtracted from the B isotope ratios in order to monitor B washout, as suggested by Foster (2008).…”
Section: Ammonia Additionmentioning
confidence: 99%
“…3 mL min −1 (AlAmmar et al, 2000;Foster, 2008). The addition of ammonia gas to the spray chamber ensures that the analyte remains alkaline, which prevents volatile boron from recondensing in the chamber during analysis (Al-Ammar et al, 2000). The measured B isotope signal of the rinse blank was then subtracted from the B isotope ratios in order to monitor B washout, as suggested by Foster (2008).…”
Section: Ammonia Additionmentioning
confidence: 99%
“…For the ammonia addition method, a dual inlet PFA Teflon spray chamber was used with an ESI PFA 50 μL/min nebuliser to add ammonia gas at a rate of ~3 mL/min (Al-Ammar et al, 2000;Foster, 2008). The addition of ammonia gas to the spray chamber ensures that the analyte remains alkaline, which prevents volatile boron from recondensing in the chamber during analysis (Al-Ammar et al, 2000).…”
Section: Ammonia Addition 265mentioning
confidence: 99%
“…The addition of ammonia gas to the spray chamber ensures that the analyte remains alkaline, which prevents volatile boron from recondensing in the chamber during analysis (Al-Ammar et al, 2000). The measured B signal of the rinse blank was then subtracted from the B isotope ratios in order to monitor B wash out, as suggested by Foster (2008).…”
Section: Ammonia Addition 265mentioning
confidence: 99%
“…Optimizando las dos primeras variables se pretendía eliminar el efecto de memoria [5,19] y la tercera variable permitió estudiar el efecto matriz causado por el calcio y el sodio sobre la medida de boro [4,9].…”
Section: Determinación De Boro Mediante Icp-oesunclassified
“…Así mismo, se han encontrado diversos trabajos [5][6][7][8][9][10][11][12][13][14][15] relacionados con el análisis de boro en otras matrices, donde se detallan las técnicas y métodos más adecuados, cómo eliminar el efecto de memoria o cómo realizar la extracción de boro [16][17][18][19].…”
unclassified