2017
DOI: 10.1016/j.sab.2016.12.006
|View full text |Cite
|
Sign up to set email alerts
|

Elemental mapping in a contemporary miniature by full-field X-ray fluorescence imaging with gaseous detector vs. scanning X-ray fluorescence imaging with polycapillary optics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 22 publications
0
14
0
Order By: Relevance
“…Obviously, the irradiance applied in our experiments was not high enough due to the limited maximum energy of the laser. Another issue is the inhomogeneous desorption process for different elements at the laser irradiance of 10 7 to 10 8 W/cm . In this manuscript, the objective of the work is focused on integrally optimizing LD‐LPI‐MS for spectral resolution, LODs, and sample consumption; therefore, non‐uniform phenomenon tends to arise.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Obviously, the irradiance applied in our experiments was not high enough due to the limited maximum energy of the laser. Another issue is the inhomogeneous desorption process for different elements at the laser irradiance of 10 7 to 10 8 W/cm . In this manuscript, the objective of the work is focused on integrally optimizing LD‐LPI‐MS for spectral resolution, LODs, and sample consumption; therefore, non‐uniform phenomenon tends to arise.…”
Section: Resultsmentioning
confidence: 99%
“…Another issue is the inhomogeneous desorption process for different elements at the laser irradiance of 10 7 to 10 8 W/cm. 2,24,25,55 In this manuscript, the objective of the work is focused on integrally optimizing LD-LPI-MS for spectral resolution, LODs, and sample consumption; therefore, non-uniform phenomenon tends to arise. Further work remains to be done to improve the quantitative capability of the LD-LPI technique.…”
Section: Improved Detection Sensitivity Of Elements In Standard Allmentioning
confidence: 99%
See 1 more Smart Citation
“…Distribution maps of calcium, copper, and gold, elements present in the used paints, were obtained. Another EDXRFI system configuration based on a 2D-THCOBRA detector (in a neon-methane atmosphere, with a 10 × 10 cm 2 active area) was used to study the elemental distribution in a contemporary Indian miniature [18]. Different regions were analysed and the results compared with results from acquisitions made with a Micro-XRF spectrometer, the M4 TORNADO (Bruker, Germany).…”
Section: Introductionmentioning
confidence: 99%
“…The GEM detectors are the most popular and widely used Micro-Pattern Gaseous Detectors (MPGD) [9][10][11][12], which are suitable for X-ray spectral imaging, despite their limited energy resolution [13,14]. They are very robust and rather easy to assemble from prefabricated components, with a variety of configurable options, allowing the sensor parameters to be adjusted to the specific requirements [15][16][17][18][19][20][21][22][23][24][25]. A standard GEM detector is assembled of copper-rich components.…”
Section: Introductionmentioning
confidence: 99%