2006
DOI: 10.1016/j.electacta.2006.02.023
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical quartz crystal impedance study on immobilization of glucose oxidase in a polymer grown from dopamine oxidation at an Au electrode for glucose sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
46
1

Year Published

2006
2006
2020
2020

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 35 publications
(49 citation statements)
references
References 43 publications
2
46
1
Order By: Relevance
“…4s caption), leading to a decrease in the deposited amount of PFDO at the same time scale, which virtually resulted in a decrease of the response current of the PFDO-Hb/Au electrode. Similar phenomena were also reported in the case for PFDO as the GOD-immobilization matrix [18]. Although the exact mechanism for this phenomenon is not very clear at present, the increased electrostatic interaction of Hb (pI ¼ 7.4) with DA (pK a ¼ 10.6 [25]) and the oligomers generated during the oxidation of DA in the polymerization buffer of pH 9.18, as well as the enhanced surface-adsorption capacity of Hb at an increased concentration, may take effect.…”
supporting
confidence: 76%
See 3 more Smart Citations
“…4s caption), leading to a decrease in the deposited amount of PFDO at the same time scale, which virtually resulted in a decrease of the response current of the PFDO-Hb/Au electrode. Similar phenomena were also reported in the case for PFDO as the GOD-immobilization matrix [18]. Although the exact mechanism for this phenomenon is not very clear at present, the increased electrostatic interaction of Hb (pI ¼ 7.4) with DA (pK a ¼ 10.6 [25]) and the oligomers generated during the oxidation of DA in the polymerization buffer of pH 9.18, as well as the enhanced surface-adsorption capacity of Hb at an increased concentration, may take effect.…”
supporting
confidence: 76%
“…We have also examined the effect of concentration of Hb on the response of the constructed electrode in a detection solution of pH 5.29 phosphate buffer, as depicted in Figure 4, where 20.0 mM phosphate buffer and 30.0 mM DA were always involved in the polymerization bath [18]. As is seen, Di ss increased with the increase in Hb concentration up to 2.00 mg mL…”
mentioning
confidence: 91%
See 2 more Smart Citations
“…The (K M ) of the system in this work was found to be 2.4 mM, implying that the Celestine blue/MWCNTs modified glassy carbon electrode exhibits a higher affinity for glucose. The value of K M for GOx in this work is much smaller than that obtained at glucose biosensors based on sol-gel organic -inorganic hybrid material, 22 mM [58], GOx immobilized at chitosan and gold nanoparticles 10.5 mM [59], GOx entrapped in polypyrrole film, 19 mM [60], GOx immobilized in dopamine polymer film 9.6 [61], GOX immobilized in nafion film, 14.91 mM [62],GOx immobilized on TiO 2 film, 6.08 mM [63] , and comparable with GOx immobilized onto nickel oxide nanoparticles, 2.7 mM [64] and GOx at edge plane of highly oriented pyrolytic graphite electrode, 2.52 mM [65].…”
Section: Amperometric Determination Of Glucose At Celestine Blue/mwcnmentioning
confidence: 98%