Electrochemical migration of directly printed Ag electrodes using Ag paste with epoxy binder

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(6 citation statements)
references
References 11 publications
(23 reference statements)
0
6
0
Order By: Relevance
“…The measured resistivity values of the 100-nm-thick Ag film/glass, patterns 1 and 2 were 0.43 × 10 −5 , 9.54 × 10 −5 and 1.98 × 10 −5 Ω cm, respectively. These values were respectively about 2.7, 60 and 12 times the bulk resistivity of Ag (1.62 × 10 −6 Ω cm) [43]. The electrical conductivity was actually thickness-dependent in the case of laser ablation of Ag films, resulting in the significant difference in resistivity of the two Ag patterns.…”
Section: Resultsmentioning
confidence: 92%
“…The measured resistivity values of the 100-nm-thick Ag film/glass, patterns 1 and 2 were 0.43 × 10 −5 , 9.54 × 10 −5 and 1.98 × 10 −5 Ω cm, respectively. These values were respectively about 2.7, 60 and 12 times the bulk resistivity of Ag (1.62 × 10 −6 Ω cm) [43]. The electrical conductivity was actually thickness-dependent in the case of laser ablation of Ag films, resulting in the significant difference in resistivity of the two Ag patterns.…”
Section: Resultsmentioning
confidence: 92%
“…[1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18] In this work, two-electrode-system was also employed to detect the failure time of circuits and in situ observe the ECM development (See Figure 1). …”
Section: Methodsmentioning
confidence: 99%
“…In order to simulate the practical service environment of electronics, two-electrode system where a bias is directly applied across the two electrodes (without a real reference electrode) was generally used. [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18] In this work, two-electrode-system was also employed to detect the failure time of circuits and in situ observe the ECM development (See Figure 1).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The investigation of the ECM of the pastes was carried out by a water drop (WD) test [22]. A 0.3 ml drop of distilled water was placed between two electrodes with a gap of 0.5 mm, and a 5 V bias voltage was applied.…”
Section: Characterizationmentioning
confidence: 99%