2010
DOI: 10.1016/j.jhazmat.2010.08.040
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical hydride generation atomic fluorescence spectrometry for detection of tin in canned foods using polyaniline-modified lead cathode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(4 citation statements)
references
References 24 publications
0
3
0
Order By: Relevance
“…Electrochemical hydride generation (EcHG), , which uses electrons supplied from the cathode as reductant, represents a suitable alternative to conventional CVG. It has been demonstrated that hydrides of several elements, including As, Hg, Bi, Sb, Pb, Ge, Te, Sn, Se, Zn, and Cd, could be achieved by EcHG. The most significant advantage of EcHG is that it obviates the need for chemical reducing reagents.…”
mentioning
confidence: 99%
“…Electrochemical hydride generation (EcHG), , which uses electrons supplied from the cathode as reductant, represents a suitable alternative to conventional CVG. It has been demonstrated that hydrides of several elements, including As, Hg, Bi, Sb, Pb, Ge, Te, Sn, Se, Zn, and Cd, could be achieved by EcHG. The most significant advantage of EcHG is that it obviates the need for chemical reducing reagents.…”
mentioning
confidence: 99%
“…Activities of GPX and SOD and concentration of malondialdehyde (MDA) were measured by the colorimetric method through the specific assay kits (A005, A001, and A003) that were purchased from the Nanjing Jiancheng Bioengineering Institute of China. Concentrations of Sn in feed and the tissues were measured using the hydride generation atomic fluorescence spectrometer (AF-610B; Beijing Rayleigh Analytical Instrument Corp., Beijing, China) as previously described [33]. Concentrations of protein were measured by the bicinchoninic acid assay [30].…”
Section: Antioxidant Enzyme Activities and Sn Concentrations Analysismentioning
confidence: 99%
“…This was calculated using the slope ratio of the linear calibration plot of the SPE-ICP-OES method in comparison to ICP-OES without the SPE method. The LOD value obtained in this study was 0.6 ng mL -1 which is comparable with the values reported in the literature as follows: 1.1 and 0.7 ng mL -1 for solid and liquid samples, respectively, by preconcentration on Saccharomyces cerevisiae and determination by ICP-OES (1), 8.4 ng mL -1 by FAAS after micelle mediated extraction (14), 0.04 ng mL -1 by quartz atom traphydride generation AAS (31), 2.86 ng mL -1 by cloud point extraction before AAS measurement (2), 0.012 ng mL -1 by graphite furnace AAS after cloud point extraction (4), and 1.5 ng mL -1 by electrochemical hydride generation atomic fluorescence spectrometry using polyaniline-modified lead cathode (32).…”
Section: Analytical Figures Of Meritmentioning
confidence: 99%