2019
DOI: 10.1007/s00604-019-3760-7
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical determination of the antipsychotic medication clozapine by a carbon paste electrode modified with a nanostructure prepared from titania nanoparticles and copper oxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0
3

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 40 publications
(8 citation statements)
references
References 35 publications
0
5
0
3
Order By: Relevance
“…The FTIR spectra of g‐C 3 N 4 also show absorption peaks at 1253, 13285, 1419, 1563, and 1639 cm −1 could be ascribed to the modes of aromatic stretching vibration, the peak at 811 cm −1 is attributed to typical 3‐s‐triazine ring vibration, and broadband between 3083 and 3289 cm −1 corresponds to the typical stretching mode of N─H 48 . The FTIR spectra of nanophotocatalyst samples show a broad absorption band at 669 cm −1 , which is attributed to the oscillation of Ti─O─Ti of black TiO 2 49 …”
Section: Resultsmentioning
confidence: 96%
“…The FTIR spectra of g‐C 3 N 4 also show absorption peaks at 1253, 13285, 1419, 1563, and 1639 cm −1 could be ascribed to the modes of aromatic stretching vibration, the peak at 811 cm −1 is attributed to typical 3‐s‐triazine ring vibration, and broadband between 3083 and 3289 cm −1 corresponds to the typical stretching mode of N─H 48 . The FTIR spectra of nanophotocatalyst samples show a broad absorption band at 669 cm −1 , which is attributed to the oscillation of Ti─O─Ti of black TiO 2 49 …”
Section: Resultsmentioning
confidence: 96%
“…In addition, the accuracy of the CLZ analytical sensor had to be compared with liquid chromatography-mass spectrometry (LC-MS) as the gold standard for small molecule quantification. [50,51] The electrochemical and LC-MS tests were performed simultaneously on a gradient-labeled standard buffer solution. The LC-MS test results showed a significant positive correlation with the developed sensor, where the R 2 was 0.9893 and the slope of the regression linear equation was 0.9707, which on the one hand, indicated that the developed sensor was capable of CLZ evaluation of the LC-MS method that was used in place of the gold standard, and on the other hand, that the developed sensor was accurate and stable over the test range (Figure S14, Supporting Information).…”
Section: Resultsmentioning
confidence: 99%
“…Fifteen minutes prior to simulated administration, rats were fixed on the experimental bench and injected with an anesthetic (0.5% pentobarbital). [ 50 ] The rats were then possessed intraperitoneal administration an amount of clozapine (50 mg kg −1 in sodium carboxymethylcellulose) by direct intragastric administration. To avoid the death of rats caused by salivary secretion into the trachea during anesthesia, tracheal intubation was performed during the test.…”
Section: Methodsmentioning
confidence: 99%
“…Thus, in this work, we aimed to compare the applicability and extraction performance of EME and SLM-LPME for non-polar basic drugs under optimal conditions toward some frequently used biological samples in forensic toxicological analysis, including whole blood, urine, saliva, and liver tissue. Clozapine, recognized as a prevalent pharmaceutical in the treatment of treatment-resistant schizophrenia, was chosen as the representative analyte for illustrative purposes [28]. Following the optimization of extraction conditions for both SLM-LPME and EME, we comprehensively compared their extraction efficiency and mass transfer capabilities.…”
Section: Introductionmentioning
confidence: 99%