2013
DOI: 10.1016/j.snb.2013.03.118
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical determination of imidacloprid using poly(carbazole)/chemically reduced graphene oxide modified glassy carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
19
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 65 publications
(27 citation statements)
references
References 35 publications
2
19
0
1
Order By: Relevance
“…Using SPC electrode, (curve 2A ---), potential cathodic peak for IMI was observed at -1.05 V with cathodic peak current of -5.10 µA. This potential value was similar to those reported using BiF [26], graphene oxide [24] and nafion/TiO 2 [27]. Using SWCNT/SPC electrode (curve 2B ---) no signal was observed for the reduction reaction.…”
Section: Electrochemical Impedance Analysis Of the Spc Swcnt/spc Andsupporting
confidence: 78%
See 2 more Smart Citations
“…Using SPC electrode, (curve 2A ---), potential cathodic peak for IMI was observed at -1.05 V with cathodic peak current of -5.10 µA. This potential value was similar to those reported using BiF [26], graphene oxide [24] and nafion/TiO 2 [27]. Using SWCNT/SPC electrode (curve 2B ---) no signal was observed for the reduction reaction.…”
Section: Electrochemical Impedance Analysis Of the Spc Swcnt/spc Andsupporting
confidence: 78%
“…Possibly, ILs acts as an extractor agent. Similar results were reported for IMI using reduced graphene on glassy carbon electrode without ILs [27]. Moreover, using ILs with carbonceramic electrode, a process controlled by diffusion for IMI was reported [3].…”
Section: Effect Of Scan Rate For Imi Using Il-swcnt/spc Electrodesupporting
confidence: 77%
See 1 more Smart Citation
“…As reported in our previous works [25], GO was prepared from graphite powder via a modified Hummer's method [26]. The GCE was polished on the fur with an alumina powder/water and then ultrasonically cleaned in deionized water before modification.…”
Section: Preparation Of Ppy/ergo/gcementioning
confidence: 99%
“…Electrochemical sensors have emerged in recent years as alternatives for pesticides detection, with benefits related to the low cost, simplicity, high sensitivity and waste reduction, among others 16,17 . The redox properties of IMD and other pesticides allow their detection through electrochemical measurements [18][19][20] .…”
Section: Introductionmentioning