2019
DOI: 10.1016/j.snb.2018.10.149
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical determination of ATP at rhodamine6G capped gold nanoparticles modified carbon felt electrode at pH 7.2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 72 publications
0
5
0
Order By: Relevance
“…To compensate the diffusion problem and restoration of mass transport, electrochemical system applied more potential and as a result, the peak potential was shifted. 53 Above results can be regarded as the contribution of the following reasons:…”
Section: Resultsmentioning
confidence: 99%
“…To compensate the diffusion problem and restoration of mass transport, electrochemical system applied more potential and as a result, the peak potential was shifted. 53 Above results can be regarded as the contribution of the following reasons:…”
Section: Resultsmentioning
confidence: 99%
“…53 From both the charge-transfer resistance and phase angle values, it was conrmed that the GNB-modied-CF electrode is more conductive than bare CF. At lower frequencies (À1.0 to 0.0 log Hz), the impedance (|Z|) value for the GNB-modied-CF electrode (72 U) is less than that of bare CF (111 U), but almost equal at 0.0 to 1.5 log Hz, and decreased at higher frequencies (1.5 to 5.0 log Hz) 32 (Fig. 6C).…”
Section: Resultsmentioning
confidence: 95%
“…6B reveals that the Bode angles for bare CF (55 ) and GNB-modied-CF (69 ) electrodes are less than 90 , which suggests that these electrodes were not behaving like an ideal capacitor. 32 Electrode electrical conductivities (s e ) of CF and the GNB-modied-CF electrode were calculated to be 9.00 Â 10 À5 and 1.38 Â 10 À4 S m À1 , corresponding to electrode resistances of 111 and 72 U m 2 , respectively. 53 From both the charge-transfer resistance and phase angle values, it was conrmed that the GNB-modied-CF electrode is more conductive than bare CF.…”
Section: Resultsmentioning
confidence: 99%
“…Reverse osmosis, ion exchange, precipitation, 6,9 electrocoagulation, 10 photodegradation, 11 photocatalyst, 12,13 electrochemical, 14 and adsorption 5,7 have been used for decolouration of Rh6G dye in aqueous systems. However, among these developed processes, it has been proved that the adsorption method is an effective purification technique due to its low cost, ease of operation, design, and environmentally friendly behaviour.…”
Section: Introductionmentioning
confidence: 99%