2013
DOI: 10.1016/j.electacta.2013.03.176
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical detection of dopamine using water-soluble sulfonated graphene

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
45
1
2

Year Published

2014
2014
2022
2022

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 121 publications
(48 citation statements)
references
References 44 publications
0
45
1
2
Order By: Relevance
“…3 was equated by the linear regression equations of I pa (μA) = −(0.4706 ± 0.0001) lgc (μM) -(0.4809 ± 0.0003) (n = 3, R 2 = 0.9939); the detection limit was calculated to be 30 nM (S/N = 3). It was lower than some previous reports [34,35], illustrating C-dots/ILgraphene/GCE possesses improved sensitivity and a wide linear range. Table 1 showed a comparison of the methods, linear ranges, and detection limits by Pd, Ni, and other nanomaterials used for electrochemically determining dopamine in a phosphate buffer media.…”
Section: Detection Of Dopaminecontrasting
confidence: 39%
“…3 was equated by the linear regression equations of I pa (μA) = −(0.4706 ± 0.0001) lgc (μM) -(0.4809 ± 0.0003) (n = 3, R 2 = 0.9939); the detection limit was calculated to be 30 nM (S/N = 3). It was lower than some previous reports [34,35], illustrating C-dots/ILgraphene/GCE possesses improved sensitivity and a wide linear range. Table 1 showed a comparison of the methods, linear ranges, and detection limits by Pd, Ni, and other nanomaterials used for electrochemically determining dopamine in a phosphate buffer media.…”
Section: Detection Of Dopaminecontrasting
confidence: 39%
“…It is also an important neurotransmitter widely distributed in the mammalian central nervous systems. It has been discovered that, the lack of DA is associated with the debilitating ailment i.e., Parkinson's disease [18,19], HIV infection and Huntington's diseases. In the past 30 years, a variety of approaches, including spectrophotometry, colorimetry, chromatography, have been developed for the DA detection by different techniques.…”
Section: Insights In Analytical Electrochemistry Issn 2470-9867mentioning
confidence: 99%
“…With sulfonating graphene, we successfully accelerated the electron transfer at the right positions while AA and UA oxidation won't happen on the sulfonated-G/GCE. [26] This modification decided the high selectivity to DA and conventional Nafion films can never hold a candle. Furthermore, by means of routine analysis in dopamine hydrochloride injection, we found the relative standard derivation (RSD, n = 5) was less than 2.0 %, indicating the real application in real pharmaceutical sample.…”
Section: For Other Detectionsmentioning