2019
DOI: 10.1007/s00216-019-02040-5
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical aptasensor for the detection of HER2 in human serum to assist in the diagnosis of early stage breast cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(14 citation statements)
references
References 35 publications
0
12
0
1
Order By: Relevance
“… Bezerra et al, 2019 ; Hideshima et al, 2018 ; Ianeselli et al, 2014 ; Jarczewska et al, 2016 ; Kiew et al, 2021 ; Kongsuphol et al, 2014 ; Macdonald et al, 2019 ; Ocaña et al, 2014 ; Wang et al, 2018 .…”
Section: Uncited Referencesunclassified
“… Bezerra et al, 2019 ; Hideshima et al, 2018 ; Ianeselli et al, 2014 ; Jarczewska et al, 2016 ; Kiew et al, 2021 ; Kongsuphol et al, 2014 ; Macdonald et al, 2019 ; Ocaña et al, 2014 ; Wang et al, 2018 .…”
Section: Uncited Referencesunclassified
“…The analytical signal referred to the current signal derived from the methylene blue redox indicator that intercalated within the double-stranded structure of aptamer. The proposed aptasensor allowed for HER2 detection in the range from 10-60 µg•L −1 with an LOD of 3 µg•L −1 [111].…”
Section: Carcinoembryonic Antigenmentioning
confidence: 99%
“…Human epidermal growth factor receptor 2 (HER2) protein is a breast cancer biomarker in the form of three domains; a transmembrane region, an intracellular tyrosine kinase domain, and an extracellular domain that can be released into the bloodstream [3][4][5]. The HER2 protein concentration in serum is less than 15 ng mL -1 (4-14 ng mL -1 ) in healthy women and overexpressed in active surveillance of patients at risk or in treatment at about > 15 ng mL -1 [6][7].…”
Section: ■ Introductionmentioning
confidence: 99%
“…A homemade screen-printed electrode modified with poly-L-lysine has been used for immobilizing HER2 aptamer by electrostatic adsorption. The biosensor exhibited an excellent interaction between the aptamer and the target protein [3]. HER2 aptamer was immobilized by a selfassembled monolayer (SAM) on the surface of the gold electrode (GE), which was pretreated with 3mercaptopropionic acid (MPA), and the sensor was able to detect HER2 concentrations ranging from 10 -5 -10 2 ng mL -1 by using electrochemical impedance spectroscopy technique [19].…”
Section: ■ Introductionmentioning
confidence: 99%