2018
DOI: 10.1016/j.diamond.2018.03.013
|View full text |Cite
|
Sign up to set email alerts
|

Electroanalytical determination of enrofloxacin based on the enhancement effect of the anionic surfactant at anodically pretreated boron-doped diamond electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
14
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 50 publications
(15 citation statements)
references
References 50 publications
1
14
0
Order By: Relevance
“…The effect of surfactants on the electrochemical process of analytes on BDDEs has been fruitfully explored along with electrochemical pretreatments, mostly by Yardim and collaborators, [234,240,243,265,[271][272][273][274][275][276] but also by others. [200,[277][278][279] Yardim et al [271] reported that the use of surfactants significantly enhanced the voltammetric response of an APT-BDDE (+ 1.30 V vs. Ag/AgCl (3 mol L À 1 NaCl)/30 s) for the polycyclic aromatic hydrocarbon benzo[a]pyrene; using SW-AdASV and the anionic surfactant sodium dodecylsulfate (SDS), this analyte was determined in the concentration range of 0.016-200 nmol L À 1 (LOD = 2.86 nmol L À 1 ) in a Britton-Robinson buffer, pH 2.0 con- APT or CPT conditions: + 0.5 A cm À 2 /30 s or À 0.5 A cm À 2 /120 s, in 0.5 mol L À 1 H 2 SO 4 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The effect of surfactants on the electrochemical process of analytes on BDDEs has been fruitfully explored along with electrochemical pretreatments, mostly by Yardim and collaborators, [234,240,243,265,[271][272][273][274][275][276] but also by others. [200,[277][278][279] Yardim et al [271] reported that the use of surfactants significantly enhanced the voltammetric response of an APT-BDDE (+ 1.30 V vs. Ag/AgCl (3 mol L À 1 NaCl)/30 s) for the polycyclic aromatic hydrocarbon benzo[a]pyrene; using SW-AdASV and the anionic surfactant sodium dodecylsulfate (SDS), this analyte was determined in the concentration range of 0.016-200 nmol L À 1 (LOD = 2.86 nmol L À 1 ) in a Britton-Robinson buffer, pH 2.0 con- APT or CPT conditions: + 0.5 A cm À 2 /30 s or À 0.5 A cm À 2 /120 s, in 0.5 mol L À 1 H 2 SO 4 .…”
Section: Discussionmentioning
confidence: 99%
“…The effect of surfactants on the electrochemical process of analytes on BDDEs has been fruitfully explored along with electrochemical pretreatments, mostly by Yardim and collaborators, but also by others . Yardim et al .…”
Section: Discussionmentioning
confidence: 99%
“…7B). On the other hand, an unknown oxidation peak at about +1.00 V was observed in blank urine samples, which could be due to the oxidation of uric acid (UA) 30,31 . After several standard additions of UA, it was observed an increasing on this oxidation peak.…”
Section: O N L I N E F I R S Tmentioning
confidence: 99%
“…The quinoline ring is an essential structure for the antibacterial action of fluoroquinolones including enrofloxacin. 3,[6][7][8] Fluorine atom is a characteristic substituent of fluoroquinolones, which is on the C 6 position of the drug, that can enhance DNA gyrase affinity, 9 increase the permeability of the bacterial cell wall, and enhance the antibacterial effect against of G + bacteria such as Staphylococcus. The introduction of piperazinyl in the C 7 position of the drug, on the one hand, improved its antibacterial activity (such as anti-Pseudomonas aeruginosa activity) and its antibacterial spectrum, on the other hand, induced the production of side effects.…”
Section: Introductionmentioning
confidence: 99%