2014
DOI: 10.1016/j.msec.2013.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Electroanalytical and naked eye determination of Cu2+ ion in various environmental samples using 5-amino-1,3,4-thiadiazole-2-thiol based Schiff bases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 31 publications
(30 reference statements)
0
7
0
Order By: Relevance
“…Compared with the reported fibrous adsorbents in Table 6 which were prepared through conventional heating, the adsorption capacities of PANMW-TSC fibers for these two metal ions were higher, and the duration of functionalization process decreased incredibly by using MW irradiation. The consumed time declined from 5-29 h to 0.5 h with higher grafting rate of N and S atoms onto the fibers which both took effects in the adsorption process [41,42].…”
Section: Comparison With Other Fibrous Adsorbentsmentioning
confidence: 98%
“…Compared with the reported fibrous adsorbents in Table 6 which were prepared through conventional heating, the adsorption capacities of PANMW-TSC fibers for these two metal ions were higher, and the duration of functionalization process decreased incredibly by using MW irradiation. The consumed time declined from 5-29 h to 0.5 h with higher grafting rate of N and S atoms onto the fibers which both took effects in the adsorption process [41,42].…”
Section: Comparison With Other Fibrous Adsorbentsmentioning
confidence: 98%
“…The action of acetyl chloride on 4-methylthiosemicarbazide produces 5-methyl-2-methylamino-1,3,4-thiadiazole 22 .…”
Section: Methodsmentioning
confidence: 99%
“…He found that by heating 4-phenylthiosemicarbazide with formic acid, 2-anilino-1,3,4-thiadiazole was formed 22 .…”
Section: Methodsmentioning
confidence: 99%
“…A 1-phenyl-2-(2-hydroxyphenylhydrazo)butane-1,3-dione (H 2 L) ionophore-based copper-selective PVC membrane electrode for precise copper analysis in soils polluted by oil was developed by Kopylovich et al [170]. Singh [171]; two polydentate Schiff bases, 4-(5-mercapto-1,3,4-thiadiazol-2-ylimino)pentan-2-one (S 1 ) and (2-(indol-3-yl)vinyl)-1,3,4-thiadiazole-2-thiol (S 2 ) [172]; and ionophores inside PVS-based solvent polymeric membranes for selective detection of Cu 2+ ions. Optimization of membrane composition, working conditions, and transducer material (classical inner liquid contact sensors vs. coated graphite electrodes, CGE, and coated pyrolytic graphite electrodes, CPGE) was performed.…”
Section: Cu(ii) Sensorsmentioning
confidence: 99%