Electrical Model of an Atmospheric Pressure Dielectric Barrier Discharge Cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
16
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(17 citation statements)
references
References 12 publications
1
16
0
Order By: Relevance
“…The DBD model involves a stray capacitance C S due to effect of the capacitance reactor, two dielectric capacitance C d1 and C d2 corresponding to dielectric material as glass, then a parallel circuit is formed; first by a series load R g -C g , and second by a current source controlled by voltage V g . Figure 11 shows the schematic and equivalent DBD proposed in (Flores et al, 2009). The goal of proposed of an electrical model is to provide more information about voltage and current values at the electrical discharge, because in the experimental set-up not only the voltages υ d (t) and υ g (t) are not measurable but also parameters are not well known because there are not conventional methods with measurement instruments.…”
Section: The Fb-fcmi Coupled To High Voltage Applicationmentioning
confidence: 99%
See 1 more Smart Citation
“…The DBD model involves a stray capacitance C S due to effect of the capacitance reactor, two dielectric capacitance C d1 and C d2 corresponding to dielectric material as glass, then a parallel circuit is formed; first by a series load R g -C g , and second by a current source controlled by voltage V g . Figure 11 shows the schematic and equivalent DBD proposed in (Flores et al, 2009). The goal of proposed of an electrical model is to provide more information about voltage and current values at the electrical discharge, because in the experimental set-up not only the voltages υ d (t) and υ g (t) are not measurable but also parameters are not well known because there are not conventional methods with measurement instruments.…”
Section: The Fb-fcmi Coupled To High Voltage Applicationmentioning
confidence: 99%
“…A considerable amount of literature has been published concerning about this kind of static power converter topology on industrial applications, for instance: STATCOM™ transport trains active filters to eliminate total harmonic distortion THD, cd to cd and cd to ca power converters, and more recently in Eolic conversion energy (Rodriguez et al, 2012;Abu et al, 2010;Fernao et al, 2012). Precedent studies about a Three Cell Flying Capacitor Inverter in half-bridge, coupled in an electrical model of a Dielectric Barrier Discharge (DBD) are presented by (Flores et al, 2009). A simulation of the electrical model is used in order to estimate the experimental results at different gas discharges, and operation frequency about 12.5 and 47 kHz implementing different commutation strategies.…”
mentioning
confidence: 99%
“…These models for the DBD include physical models [11]- [13] and electrical models [6], [7], [14]- [17]. The physical models are based on fluid equations involved with charged partial movements and boundary conditions.…”
Section: Introductionmentioning
confidence: 99%
“…The cold plasma can be applied to the load of interest; yet, in the mutually distinctive range of applications, the operating voltage and power may become highly different under various scenarios [3], [4]. To cope with various situations, a common method is to develop a special power driver, where either dc or ac power is suitable [5]- [10]. However, it is noted that when the dc source is applied, the charges are often accumulated on the dielectric surface, hindering the progress of circuit discharging.…”
Section: Introductionmentioning
confidence: 99%
“…Worst of all, once the charge has accumulated to a certain level, it becomes prone to arcing, often bringing difficulty of plasmacontrol performance. On the contrary, by choosing the ac source to enact a preionization to facilitate the glow discharge, the required frequency may be up to several kilohertz [5], [6].…”
Section: Introductionmentioning