2007
DOI: 10.1016/j.sab.2007.07.003
|View full text |Cite
|
Sign up to set email alerts
|

Electrical measurements at radio frequency glow discharges for spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 88 publications
(179 reference statements)
1
14
0
Order By: Relevance
“…For a free running generator no matching box is needed because the source is a part of the oscillating circuit. 36,37 This simplifies the generator operation and reduces the stabilisation time. The oscillation frequency changes slightly and thus compensates the variation of the plasma impedance.…”
Section: Optimization Of the Experimental Setupmentioning
confidence: 99%
“…For a free running generator no matching box is needed because the source is a part of the oscillating circuit. 36,37 This simplifies the generator operation and reduces the stabilisation time. The oscillation frequency changes slightly and thus compensates the variation of the plasma impedance.…”
Section: Optimization Of the Experimental Setupmentioning
confidence: 99%
“…For ultra thin non-conductive layers the capacity is very high, and thus, the voltage drop is negligible. 12,25 But in the case of thick nonconductive samples V out /V in is less than 1 due to the low sample capacitance and the resultant voltage drop with the consequent lower power deposition into the discharge plasma. This study is based on a simplified equivalent electrical circuit for the system, which has been described previously by Therese et al, 12 taking into account the capacitances of the discharge cell, sample and probes used.…”
Section: Electrical Measurements: Voltage Transfer Coefficientmentioning
confidence: 99%
“…However, there are also non-conducting oxide films whose dc bias voltages can not be determined. Fortunately, interesting progresses both in instrumentation 30 and in the development of numerical and electrical simulations 31 are being made to solve remained limitations in the analysis of non-conducting samples.…”
Section: Gd-oes Calibration Of Oxygenmentioning
confidence: 99%
“…The Al/O ratio reached a constant value at the same time that hydrogen concentration diminished from 3 to 0.6 mass% (although hydrogen quantification should be taken with care). Wilken et al 30 have recently reported that the porous Al 2 O 3 layer of the electrochemical oxidation is usually densified by water vapour to Bo ¨hmit (2 AlO(OH)). The challenging differentiation of aluminium oxide, oxo-hydroxides and hydroxides by XPS was carried out using Thomas' protocol.…”
Section: Compositional Depth Profiling Analysis Of Anodic Alumina Filmsmentioning
confidence: 99%