2016
DOI: 10.1017/wpt.2016.8
|View full text |Cite
|
Sign up to set email alerts
|

Electrical excitation of the local earth for resonant, wireless energy transfer

Abstract: Here we demonstrate wireless energy transfer that exploits the conductivity and permittivity of soil to create a potential gradient on the surface around an earthed electrode, distributing electrical energy over the area. This generated surface potential can be amplified using a special standing-wave receiver for harnessing the distributed energy. We have experimentally mapped the surface potential around the electrode and plotted the received energy covering an area of 1200 m 2 . Key operating parameters are … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
7
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
3
2

Relationship

3
5

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 24 publications
(27 reference statements)
0
7
0
Order By: Relevance
“…This pulls the reference potential of the metal to the same level as the grid ground. Thus, metal is transformed into a neutral entity 26 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…This pulls the reference potential of the metal to the same level as the grid ground. Thus, metal is transformed into a neutral entity 26 .…”
Section: Resultsmentioning
confidence: 99%
“…There exist many practical scenarios consisting of metallic infrastructures, such as nuclear plants, railway tracks, space ships, steel building structures, pipelines, etc. Practical applications include powering Internet of things (IoT) devices, charging for -marine vessels, smart manufacturing floors, and secured shipping containers [24][25][26] .…”
mentioning
confidence: 99%
“…This pulls the reference potential of the metal to the same level as the grid ground. Thus, metal is transformed into a neutral entity 28 . The metal's behavior as a neutral point is covered in the supplementary material(section 3).…”
Section: Resultsmentioning
confidence: 99%
“…Conservatively, the current density should not exceed 200 A/m 2 , in the vicinity of the grounded electrode for more than one second (Meijer, 1995). The efficient grounding was experimentally shown to result to maximum and efficient power transfer (Neste et al, 2016), albeit that was a wireless system.…”
Section: …………………… (8)mentioning