2019
DOI: 10.1016/j.watres.2019.01.058
|View full text |Cite
|
Sign up to set email alerts
|

Electric-field enhanced reactivity and migration of iron nanoparticles with implications for groundwater treatment technologies: Proof of concept

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2
2

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(3 citation statements)
references
References 39 publications
0
3
0
Order By: Relevance
“…Such a low value of ORP may indicate that the concentration of μZVI used in the batch tests was fairly high, as was also reported in study [29] when a low ORP was reached in a highly concentrated system. Due to this, the ORP stayed low compared to the control and also for a longer period of time compared to the previously published data, where nZVI at a low concentration was used and the ORP began to increase after five days [30]. A decrease in the ORP is accompanied with an increase in the pH up to a value of 10.2, which is due to the reduction of water (e.g.…”
Section: Chemistry -Ce Degradation Orp and Phmentioning
confidence: 53%
“…Such a low value of ORP may indicate that the concentration of μZVI used in the batch tests was fairly high, as was also reported in study [29] when a low ORP was reached in a highly concentrated system. Due to this, the ORP stayed low compared to the control and also for a longer period of time compared to the previously published data, where nZVI at a low concentration was used and the ORP began to increase after five days [30]. A decrease in the ORP is accompanied with an increase in the pH up to a value of 10.2, which is due to the reduction of water (e.g.…”
Section: Chemistry -Ce Degradation Orp and Phmentioning
confidence: 53%
“…The decrease of the ORP has the same trend in all reactors because of reductive capacity of nZVI and applied DC, which lowering ORP even alone. [8] Nevertheless, in the reactor 1, decreasing reductive ability occurs when the ORP slowly increase. The level of conductivity in the reactor can be attributed to several factors.…”
Section: Ph Orp Conductivity Development Within Reductive Dechlorinationmentioning
confidence: 99%
“…Nanowire-assisted disinfection water treatment technology [8] was introduced when nanotechnology was combined with a field enhancement treatment. In the application of field-enhanced nanoparticles in groundwater treatment [9], when a DC voltage is applied to wastewater that is rich in special particles, the degree of aggregation of nano-particles is lower, which increases the interactions between nano-particles and silicon dioxide and improves the reactivity and persistence of nano-particles, depending on the characteristics of the distribution of the local electric field between nano-particles and the interactions between nano-particles under an electric field.…”
Section: Introductionmentioning
confidence: 99%