Electric current as a source of information about control parameters of indirect injection fuel injector

Abstract: The article discusses results of the laboratory experiments in which fuel injectors used in indirect injection internal combustion engines were tested. During the experiments, numerous dosing cycles of the injectors were performed while changing the control parameters, due to which, the dosing characteristics were developed and influence of applied parameters on the resultant fuel flow determined. Simultaneously, the voltage and electric current waveforms in the injector coil were recorded, due to which findin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(14 citation statements)
references
References 13 publications
(20 reference statements)
2
10
0
Order By: Relevance
“…The current measured by a handheld device in acceleration phase is i a = 1.24 A, during measurement, i m = 0.37 A, and during deceleration, i d = −0.19 A. This is adequate to magnetic flux densities measured 0.6 m from the power cable B a = 0.07 × 10 −7 T, B m = 0.02 × 10 −7 T, B d = −0.009 × 10 −7 T calculated using Biot-Savart law [ 17 , 25 ]. Please note that B m is significantly lower than the HMC5883L magnetic sensor’s resolution and accuracy, which is 0.48 × 10 −7 T and 2 × 10 −7 T accordingly.…”
Section: Methodssupporting
confidence: 59%
“…The current measured by a handheld device in acceleration phase is i a = 1.24 A, during measurement, i m = 0.37 A, and during deceleration, i d = −0.19 A. This is adequate to magnetic flux densities measured 0.6 m from the power cable B a = 0.07 × 10 −7 T, B m = 0.02 × 10 −7 T, B d = −0.009 × 10 −7 T calculated using Biot-Savart law [ 17 , 25 ]. Please note that B m is significantly lower than the HMC5883L magnetic sensor’s resolution and accuracy, which is 0.48 × 10 −7 T and 2 × 10 −7 T accordingly.…”
Section: Methodssupporting
confidence: 59%
“…The purpose of the pressure coefficient ( ) [ 32 ] is to obtain the modeled electric current value in the range according to the actual value. Depending on the modeled waveform segment, this coefficient takes different values.…”
Section: Resultsmentioning
confidence: 99%
“…By decreasing fuel consumption, it decreases carbon emission and other greenhouse gases emission. The current also gives us the characteristics of its fuel injection system [18]. Fig.…”
Section: Hybrid Motorbikementioning