2005
DOI: 10.1109/tpel.2005.854024
|View full text |Cite
|
Sign up to set email alerts
|

Efficiency Optimization in ZVS Series Resonant Inverters With Asymmetrical Voltage-Cancellation Control

Abstract: This paper presents a time-domain analysis and a computerized search algorithm for optimizing the efficiency in zero-voltage switching (ZVS) full-bridge series resonant inverters with asymmetrical voltage-cancellation (AVC) control for different load quality factors. The optimum AVC control found allows all the switches to be turned on with zero voltage with the minimum switching frequency. In order to minimize losses, the switching frequency is kept as close as possible to resonance. The optimum AVC control i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0
2

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 53 publications
(24 citation statements)
references
References 15 publications
0
22
0
2
Order By: Relevance
“…There are mainly three narrow frequency-range control techniques used for the control of resonant converters, namely asymmetrical duty cycle (ADC), asymmetrical clamped mode (ACM), and symmetrical clamped mode (SCM) control. It has been shown in [19][20][21] that only ACM control has the best performance in terms of the least losses in the inverter switches as compared to other two control strategies and has the lowest …”
Section: Small-signal Modelingmentioning
confidence: 99%
See 2 more Smart Citations
“…There are mainly three narrow frequency-range control techniques used for the control of resonant converters, namely asymmetrical duty cycle (ADC), asymmetrical clamped mode (ACM), and symmetrical clamped mode (SCM) control. It has been shown in [19][20][21] that only ACM control has the best performance in terms of the least losses in the inverter switches as compared to other two control strategies and has the lowest …”
Section: Small-signal Modelingmentioning
confidence: 99%
“…Table 1 gives the parameters of the experimental setup. Using theories presented in [19][20][21], and depending on availability of capacitors in the market, f S was calculated to be 41.426 kHz for ensuring ZVS for any variation of α, and the primary coil was tuned to a resonant frequency of 39.031 kHz.…”
Section: Verification Of Small-signal Model and Design Of Control Loopsmentioning
confidence: 99%
See 1 more Smart Citation
“…This method achieves higher efficiency as compared to PSC and ADC [30] by reducing conduction loss and turn off losses without losing ZVS condition.. In AVC, the voltage is only clamped to zero on one side, asymmetrically [31]. …”
Section: Asymmetrical Voltage Cancellation (Avc) Control Of Srimentioning
confidence: 99%
“…2013. mayor utilización de la electrónica y conmutación por ZVS. Barragán et al [43] desarrollaron un algoritmo de optimización de la eficiencia de un IRS en onda completa en puente con ZVS y un control por cancelación de voltaje asimétrico para diferentes factores de calidad de la carga analizada. Con el desarrollo se logró una eficiencia del 93 % con el 10 % de la carga y el 96 % con el 100 % de la carga [43].…”
Section: Control Por Cancelación De Voltaje Asimétrico (Avc)unclassified