2015
DOI: 10.1016/j.apenergy.2015.06.025
|View full text |Cite
|
Sign up to set email alerts
|

Efficiency and operational behaviour of small-scale pellet boilers installed in residential buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
19
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(21 citation statements)
references
References 16 publications
2
19
0
Order By: Relevance
“…Full load hours also show a significant correlation. Because Spearman's rho is higher than Pearson coefficient, a non-linear function might be better than a linear function to correlate the two quantities (see also Carlon et al [41]). Finally, both methods show weak correlations with operating hours per year, full load hours per year, and runtime per ignitions.…”
Section: All Buildingsmentioning
confidence: 98%
“…Full load hours also show a significant correlation. Because Spearman's rho is higher than Pearson coefficient, a non-linear function might be better than a linear function to correlate the two quantities (see also Carlon et al [41]). Finally, both methods show weak correlations with operating hours per year, full load hours per year, and runtime per ignitions.…”
Section: All Buildingsmentioning
confidence: 98%
“…The traditional open fireplaces have efficiencies lower than 20% [158] and should not be considered a heating solution. At the high end of the range, wood pellet boilers can achieve efficiencies of more than 90% [159]. The scale of nondomestic applications is very variable and can go up to several MW th .…”
Section: Heating Applicationsmentioning
confidence: 99%
“…Steam turbines are a mature technology and applied in a wide range of powers. However, in small decentralized plants their electrical efficiency is low [159]. In this case, CHP plants should be operated in a heat-controlled mode with low power-to-heat ratios [159].…”
Section: Chp Applicationsmentioning
confidence: 99%
“…Compared with the conventional building, in this building, electricity can be obtained directly by the grid, and heat can be obtained from the gas grid via a boiler which burns gas to generate heat with the overall heat efficiency is assumed to be 88% [24]. Adding a high cost, high efficiency energy generator-a micro-CHP unit-in the building represents the main distinction from a conventional building.…”
Section: System Definitionmentioning
confidence: 99%