2019
DOI: 10.3892/etm.2019.7597
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy of nickel‑titanium memory alloy in the treatment of multiple rib fracture combined with sternal fracture

Abstract: Clinical efficacy and complications of nickel-titanium memory alloy in the treatment of multiple rib fractures combined with sternal fractures was investigated. A retrospective analysis of 123 patients with multiple rib fractures combined with sternal fractures admitted to First People's Hospital of Fuzhou from January 2013 to December 2015 was performed, including study group (treated with internal fixation by the nickel-titanium memory alloy, n=68) and control group (treated with internal fixation by partial… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 24 publications
0
2
0
Order By: Relevance
“…While in our study, only one patient was treated with mild steel wire displacement, clinicians have also reported good results using steel wire with a needle similar to that used in cardiac surgery to fix the fracture (25). Nickel-titanium memory alloy embracing fixator is a new type of material combining sensing with actuation (26). It is widely used for sternal fracture in our medical center and has favorable histocompatibility, excellent corrosion resistance, and self-pressurized function.…”
Section: Discussionmentioning
confidence: 99%
“…While in our study, only one patient was treated with mild steel wire displacement, clinicians have also reported good results using steel wire with a needle similar to that used in cardiac surgery to fix the fracture (25). Nickel-titanium memory alloy embracing fixator is a new type of material combining sensing with actuation (26). It is widely used for sternal fracture in our medical center and has favorable histocompatibility, excellent corrosion resistance, and self-pressurized function.…”
Section: Discussionmentioning
confidence: 99%
“…Using rib fixation plates firstly comes into our minds when we encounter a patient with rib fractures [12]. However, it is not suitable for those severe patients who have too many fractured sites and large fractured areas both in ribs and sternum, especially with cartilage fractures.…”
Section: Discussionmentioning
confidence: 99%