2021
DOI: 10.1111/jce.14957
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy of LGE‐MRI‐guided fibrosis ablation versus conventional catheter ablation of atrial fibrillation: The DECAAF II trial: Study design

Abstract: Introduction Success rates of catheter ablation in persistent atrial fibrillation (AF) remain suboptimal. A better and more targeted ablation strategy is urgently needed to optimize outcomes of AF treatment. We sought to assess the safety and efficacy of targeting atrial fibrosis during ablation of persistent AF patients in improving procedural outcomes. Methods The DECAAF II trial (ClinicalTrials. gov identifier number NCT02529319) is a prospective, randomized, multicenter trial of patients with persistent AF… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
66
0
2

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 63 publications
(69 citation statements)
references
References 41 publications
1
66
0
2
Order By: Relevance
“…The copyright holder for this preprint this version posted February 5, 2022. ; https://doi.org/10.1101/2022.02.02.22269817 doi: medRxiv preprint that ablation of LGE-areas in the DECAAF II study did not improve sinus rhythm maintenance rates, indicates that the detected LGE-areas (using the Utah-method) may not have a major arrhythmogenic role in human AF [19].…”
Section: Complementarity Of Mapping Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…The copyright holder for this preprint this version posted February 5, 2022. ; https://doi.org/10.1101/2022.02.02.22269817 doi: medRxiv preprint that ablation of LGE-areas in the DECAAF II study did not improve sinus rhythm maintenance rates, indicates that the detected LGE-areas (using the Utah-method) may not have a major arrhythmogenic role in human AF [19].…”
Section: Complementarity Of Mapping Systemsmentioning
confidence: 99%
“…In this way, the most sensitive and specific LGE-extent was determined to detect significant LA-LVS. A fibrotic tissue extent ≥20% of the total LA-wall (Utah-stages III and IV) was classified as relevant LGE for the Utah method [19].…”
mentioning
confidence: 99%
“…Fibrosis introduces heterogeneities in electrical repolarization and conduction, which can facilitate multiple wavelet re-entry or anchor driver regions in optical mapping studies of human AF [ 63 ]. It remains unclear how best to quantify fibrosis clinically, although groups have used signal intensity on gadolinium-enhanced magnetic resonance imaging [ 64 ] and low-amplitude electrograms in electrophysiology study [ 65 ].…”
Section: Pathophysiology For Af At the Cellular Levelmentioning
confidence: 99%
“…The other scan parameters for Cine of LV scan were TR = 3.48 ms, TE = 1.74 ms, FA = 90 o . Scan protocol for 3D LGE was similar to 3D LGE protocol optimized and validated in DECAAF and DECAAF II multi-center studies (18). LGE scan was initiated 20-25 minutes after contrast agent administration using a 3D inversion recovery prepared, respiration navigated, ECG-gated, spoiled gradient echo pulse sequence.…”
Section: Cmr Study Protocolmentioning
confidence: 99%