2007
DOI: 10.1016/j.ajo.2006.11.045
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy of Different Intraocular Lens Materials and Optic Edge Designs in Preventing Posterior Capsular Opacification: A Meta-Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
97
0
6

Year Published

2008
2008
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 104 publications
(104 citation statements)
references
References 38 publications
1
97
0
6
Order By: Relevance
“…(Cheng, Wei et al 2007;Li, Chen et al 2008;Findl, Buehl et al 2010) The neodymium:YAG capsulotomy rate for acrylic and silicone IOLs was comparable. (Cheng, Wei et al 2007;Li, Chen et al 2008;Findl, Buehl et al 2010) In addition, sharp-edged acrylic and sharp-edged silicone IOLs were significantly more effective than round-edged IOLs in the prevention of PCO and neodymium:YAG capsulotomy. (Cheng, Wei et al 2007;Findl, Buehl et al 2010) Currently available toric IOLs all have a sharp-edged design (Acrysof toric, Rayner toric, Acri.Comfort toric and MicroSil toric), or an almost sharp-edged design (STAAR toric).…”
Section: Posterior Capsule Opacificationmentioning
confidence: 89%
See 2 more Smart Citations
“…(Cheng, Wei et al 2007;Li, Chen et al 2008;Findl, Buehl et al 2010) The neodymium:YAG capsulotomy rate for acrylic and silicone IOLs was comparable. (Cheng, Wei et al 2007;Li, Chen et al 2008;Findl, Buehl et al 2010) In addition, sharp-edged acrylic and sharp-edged silicone IOLs were significantly more effective than round-edged IOLs in the prevention of PCO and neodymium:YAG capsulotomy. (Cheng, Wei et al 2007;Findl, Buehl et al 2010) Currently available toric IOLs all have a sharp-edged design (Acrysof toric, Rayner toric, Acri.Comfort toric and MicroSil toric), or an almost sharp-edged design (STAAR toric).…”
Section: Posterior Capsule Opacificationmentioning
confidence: 89%
“…Two metaanalyses and one Cochrane systematic review have been published concerning the PCO and neodymium:YAG capsulotomy rates of different IOL biomaterials and optic edge designs. (Cheng, Wei et al 2007;Li, Chen et al 2008;Findl, Buehl et al 2010) Silicone IOLs were associated with lower PCO rates than acrylic IOLs, but this difference did not reach statistical significance in the Cochrance systematic review. (Cheng, Wei et al 2007;Li, Chen et al 2008;Findl, Buehl et al 2010) The neodymium:YAG capsulotomy rate for acrylic and silicone IOLs was comparable.…”
Section: Posterior Capsule Opacificationmentioning
confidence: 99%
See 1 more Smart Citation
“…15 Acrylic IOLs are associated with a lower rate of capsule opacity than rigid PMMA lenses. It is possible that a longer follow-up period would show an increased benefit from foldable acrylic IOL as the rigid PMMA IOL are more affected by capsule opacity.…”
Section: Discussionmentioning
confidence: 99%
“…Para assegurar a qualidade metodológica, os autores avaliaram, de forma independente, os seguintes critérios com respectiva pontuação baseada em publicação prévia (9) : método de alocação, ocultação da alocação, suspensão do uso da toxina botulínica, cálculo do tamanho da amostra e validação externa (critérios de inclusão e exclusão). Foi expressa uma pontuação para cada trabalho de acordo com sua qualidade metodológica e uma pontuação mínima de quatro (em um total de oito pontos possíveis) foi exigida para a inclusão do trabalho no presente estudo.…”
Section: Métodosunclassified