2017
DOI: 10.1016/j.msec.2017.05.060
|View full text |Cite
|
Sign up to set email alerts
|

Effects of the surface modification of polyurethane substrates on genotoxicity and blood activation processes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…The same method has been used elsewhere. 26 The test is based on the cone and plate analyser, an instrument validated for clinical use in the evaluation of thrombotic diseases. The shear test was applied at shear rate 1800 s (720 r/min) for 300 s, using a disposable teflon conical rotor.…”
Section: A Simplified Methods To Assess Haemocompatibility Under High mentioning
confidence: 99%
See 3 more Smart Citations
“…The same method has been used elsewhere. 26 The test is based on the cone and plate analyser, an instrument validated for clinical use in the evaluation of thrombotic diseases. The shear test was applied at shear rate 1800 s (720 r/min) for 300 s, using a disposable teflon conical rotor.…”
Section: A Simplified Methods To Assess Haemocompatibility Under High mentioning
confidence: 99%
“…The technique of the flow cytometry analyses has been described elsewhere. 26 Briefly, 5 μL aliquots of blood were gently mixed with fluorochrome-conjugated monoclonal antibodies: 5 μL of fluorescein isothiocyanate (FITC)-PAC-1, 5 μL of PE-CD62P and 4 μL of Peridinin-Chlorophyll-protein (PerCP)-CD61 (all from Becton Dickinson, USA) in phosphate buffered saline (PBS) containing 0.2% bovine serum albumin and 2 mM calcium chloride (final volume 35 μL). After 10 min of staining at room temperature, erythrocytes were lysed by the addition of 0.5 mL of lysing solution (FLS; Becton Dickinson), and platelets were centrifuged (1000× g , 6 min) and resuspended in a PBS buffer for further analyses by flow cytometry.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Coating of titanium-based substrates was performed by physical vapor deposition and plasma-enhanced chemical vapor deposition (PECVD). A more detailed description is presented elsewhere [6]. Briefly, substrates were ultrasonically cleaned in alcohol and acetone to remove any contaminants on the surface.…”
Section: Surface Modificationmentioning
confidence: 99%