2020
DOI: 10.1039/d0ra02502j
|View full text |Cite
|
Sign up to set email alerts
|

Effects of temperature and humidity on the performance of a PECH polymer coated SAW sensor

Abstract: The influences of environment, such as temperature, humidity and interfering gases, on the performance of a surface acoustic wave (SAW) sensor in the detection of 2-chloroethyl ethyl sulfide (CEES) were invested.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 31 publications
0
14
0
Order By: Relevance
“…Despite this problem, gas sensors are used constantly; nonetheless, this can be very dangerous for firefighters especially in cases where they are exposed to explosive gases. Pan et al 191 Acoustic wave sensor (SAW)…”
Section: Discussionmentioning
confidence: 99%
“…Despite this problem, gas sensors are used constantly; nonetheless, this can be very dangerous for firefighters especially in cases where they are exposed to explosive gases. Pan et al 191 Acoustic wave sensor (SAW)…”
Section: Discussionmentioning
confidence: 99%
“…The solvation properties of PECH are determined by dipolar chloromethyl groups and slightly basic ether linkages. The interaction of PECH with sulfur mustard is likely to be Van der Waals interactions and the formation of hydrogen bonds in which PECH is donor of hydrogen [ 55 , 57 ]. However, the contribution of formation of hydrogen bonds of this type has been questioned in some work [ 58 ].…”
Section: Detection Of Blister Agents and Their Simulants Using Acoust...mentioning
confidence: 99%
“…Currently, research on the use of PECH in sensors for the detection blister agents is still being continued. Interesting results have been presented in the works that have appeared in recent years [ 54 , 57 ].…”
Section: Detection Of Blister Agents and Their Simulants Using Acoust...mentioning
confidence: 99%
“…The piezoelectric, mass-sensitive, or acoustic wave tools present label-free and quick detection of molecules due to mass, which is the main feature of each molecule. These transducers include (i) the surface acoustic wave (SAW) devices [41,42]; (ii) the bulk acoustic wave (BAW) devices and quartz crystal microbalance (QCM) devices [43][44][45][46]; and (iii) the shear transverse wave (STW) devices [47], which are constantly combining with various bioreceptor elements for biomedical diagnosis and molecular recognition [48]. Quartz crystal microbalance biosensors are needed for the determination of a broad variety of biomolecules.…”
Section: Biosensor Devicesmentioning
confidence: 99%