Effects of phacoemulsification time on the corneal endothelium using phacofracture and phaco chop techniques

Abstract: The phaco chop technique led to shorter phacoemulsification time and less endothelial cell loss.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
86
1
4

Year Published

2006
2006
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 120 publications
(97 citation statements)
references
References 2 publications
2
86
1
4
Order By: Relevance
“…19,[25][26][27] It is known that endothelial cell survival depends on the type of OVD used. 11,12,15,18 It is unclear whether ECL decreases using phaco chop technique during fluid-based phacoemulsification.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…19,[25][26][27] It is known that endothelial cell survival depends on the type of OVD used. 11,12,15,18 It is unclear whether ECL decreases using phaco chop technique during fluid-based phacoemulsification.…”
Section: Discussionmentioning
confidence: 99%
“…The results on mean ECL vary from 0.4 to 27.7% after phacoemulsification, depending on different surgical techniques. 2,[4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20] In recent years, new surgical procedures have been developed to reduce ECL, such as laserand fluid-based methods. During the latter procedure, short pulses (4 ml) of warmed balanced salt solution liquefy the lens material, while the irrigation fluid surrounds the warmed pulsating fluid allowing cooling of the pulse.…”
Section: Introductionmentioning
confidence: 99%
“…Preoperative parameters include older age, constricted pupil, firmness of the nucleus, and shorter axial length (AL) (1)(2) . Intraoperative factors include the incision size and design, Descemet membrane detachment, toxic intraoperative medications, phacoemulsification technique, and the type of ophthalmic viscosurgical device (OVD) used (1)(2)(3)(4) .…”
Section: Introductionmentioning
confidence: 99%
“…presence of air bubbles, release of free radicals), low surgeon experience, and postoperative inflammation (3)(4)(5)(6) . To reduce the energy applied, aspects related to the phacoemulsifier such as ultrasound modes, special tips, microprocessors, and high-vacuum systems must be considered.…”
Section: Introductionmentioning
confidence: 99%
“…Estes resultados têm sido notados na prática clínica, mas os dados de literatura relacionando redução de energia térmica com os novos equipamentos e técnicas ainda são escassos (8)(9)(10) .…”
Section: Métodosunclassified