The AcrySof IQ IOL with a modified posterior surface induced significantly less HOA and spherical aberration than the AcrySof Natural IOL. Contrast sensitivity was better under mesopic conditions with the AcrySof IQ IOL.
Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Tecnis ZM900 multifocal IOL implantation were included in this retrospective analysis. The minimum followup of 3 months was required after the surgery. Patients were assessed for uncorrected near visual acuity (UNVA) at a fixed distance (33 cm), uncorrected intermediate visual acuity (UIVA) at 60 cm, and uncorrected distance visual acuity (UDVA). Using a subjective questionnaire, patients satisfaction, their independence from using glasses, and the perception of glare and halo phenomena were also evaluated at the last follow-up. Results. Two thousand and five hundred eyes of 1558 patients underwent cataract surgery and Tecnis ZM900 multifocal IOL implantation. Four hundred and eighty seven patients (31.3%) were men, and 1071 (68.7%) were women. The mean age of the patients was 66.17 years. A UDVA of 20/30 or better was achieved by 85% of eyes. A UNVA of J1 was achieved by 93.7% of eyes and that of J2 or better was achieved by 98%. A UIVA of J4 or better was achieved by 65% and J5 or better was achived by more than 82.8% of the eyes in the study. Glare and halos were reported as severe by only 6.1% and 2.12% of patients, respectively. Ninety seven percent reported complete spectacle independence and 88% stated that they are totally satisfied with their quality of vision and would choose to have the same lens implanted again after the first implant. Five percent of the eyes in the study needed a second procedure (enhancement) to achieve a better visual result. No patient underwent lens exchange. Conclusion. Excellent near, intermediate, and distant vision was observed in patients implanted with the Tecnis ZM900 diffractive multifocal IOL. Spectacle independence and a minimum occurrence of photic phenomena make this IOL an excellent option in patients with cataract.
We report a case of Ferrara intracorneal ring (Mediphacos) implantation and cataract surgery for the correction of pellucid marginal corneal degeneration. Preoperatively, the patient's uncorrected visual acuity (UCVA) was 0.05 in the right eye and 0.10 in the left eye. The best spectacle-corrected visual acuity (BSCVA) was 0.50 with -2.00 -11.25 x 80 in the right eye and 0.60 with -2.00 -5.50 x 95 in the left eye. One month postoperatively, the UCVA was 0.50 in the right eye and 0.30 in the left eye. The BSCVA was 0.80 with -1.00 in the right eye and 0.60 with -0.75 -1.25 x 160 in the left eye. Ferrara intrastromal rings and cataract surgery resulted in a more regular corneal shape with a reduction in astigmatism for good visual recovery.
Piggyback implantation using the ReSTOR IOL appeared to be a safe and efficient procedure providing high-quality visual acuity for near and distance vision in selected patients.
Primary piggyback implantation using the Tecnis ZM900 multifocal IOL was a simple, safe, and accurate option for patients with high hyperopia who wanted to reduce their dependency on spectacles.
Introduction: During aging there is a close relationship between visual deficits, imbalance and falls, and eye surgery can be an efficient treatment option for elderly persons. Objective: Evaluate the influence of visual conditions on patients suffering from senile cataract with increasing imbalance. Method: A descriptive and analytical study using a quantitative longitudinal cohort technique was conducted. The study included 30 individuals who were evaluated before and 30 and 60 days after surgery. The Mini Mental State Examination (MMSE), Berg Balance Scale (BBS), Short Physical Performance Battery (SPPB), International Falls Efficacy Scale adapted for Brazil (FES-I) and a medical history questionnaire were used to collect data. Statistical analysis involved the Chi-squared, Student's t and Mann-Whitney tests. Values of p<0.05 were considered significant. Results: The SPPB found that of 15 elderly women, 13 (87%) achieved moderate performance of the lower limbs while the performance of two (13%) remained poor, after 60 postoperative days. The FES-I revealed that three (20%) elderly persons were mildly worried about falls 60 days post-surgery. Of the 15 elderly male subjects evaluated by BBS, before and at 30 and 60 days after surgery, one (7%), managed to maintain some balance but needed assistance; while 14 (93%) maintained good balance. The SPPB found that the performance of five elderly persons (33%) was moderate and that of nine (67%) was good. Conclusion: Senile cataract surgery had positive preventative effects on lower limb performance, balance and fear of falling among the elderly studied, preventing the falls and fractures that are common during aging.
Early outcomes indicate that anterior optic capture is a safe, accurate procedure in eyes with multifocal IOLs and a mild hyperopic residual refractive error postoperatively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.