2018
DOI: 10.1016/j.mtcomm.2018.08.012
|View full text |Cite
|
Sign up to set email alerts
|

Effects of low temperature buffer on carbon nano wall’s growth

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 40 publications
0
2
0
Order By: Relevance
“…In addition, the G band (Lorentzian) and D′ band (Gaussian) supported the aforementioned assumption. In AT‐CNT, the peak near 1600 cm −1 had a broader peak due to the high intensity of the D′ band and a small difference between the positions of the G and D′ bands, but these two bands were clearly separated in TEMPO‐CNT 64,66 . Owing to these differences in the G and D′ bands, the intensity ratio of the D and G band (I D /I G ) representing the inhomogeneities of the tube size and defect degree of AT‐CNT showed 1.27, while the I D /I G of TEMPO‐CNT was 1.14 67,68 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the G band (Lorentzian) and D′ band (Gaussian) supported the aforementioned assumption. In AT‐CNT, the peak near 1600 cm −1 had a broader peak due to the high intensity of the D′ band and a small difference between the positions of the G and D′ bands, but these two bands were clearly separated in TEMPO‐CNT 64,66 . Owing to these differences in the G and D′ bands, the intensity ratio of the D and G band (I D /I G ) representing the inhomogeneities of the tube size and defect degree of AT‐CNT showed 1.27, while the I D /I G of TEMPO‐CNT was 1.14 67,68 .…”
Section: Resultsmentioning
confidence: 99%
“…In AT-CNT, the peak near 1600 cm À1 had a broader peak due to the high intensity of the D 0 band and a small difference between the positions of the G and D 0 bands, but these two bands were clearly separated in TEMPO-CNT. 64,66 Owing to these differences in the G and D 0 bands, the intensity ratio of the D and G band (I D /I G ) representing the inhomogeneities of the tube size and defect degree of AT-CNT showed 1.27, while the I D /I G of TEMPO-CNT was 1.14. 67,68 These results showed that the TEMPO-CNT had higher structural uniformity and lowdefected features than AT-CNT, although their oxygencontaining functional group contents were practically identical.…”
Section: Chemical Structure Of Tempo-cntmentioning
confidence: 99%