2015
DOI: 10.2116/analsci.31.61
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Densities of Brominated Flame Retardants on the Detection Response for HPLC Analysis with a Corona-charged Aerosol Detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 23 publications
(31 reference statements)
0
8
0
Order By: Relevance
“…It is often stated that the surface area, and therefore CAD response, should be directly proportional to the mass of analyte to the power 2/3. On the basis of recent observations of density affecting CAD response, this needs to be revised. The CAD response should actually be proportional to the mass of analyte divided by its density to the power 2/3. …”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…It is often stated that the surface area, and therefore CAD response, should be directly proportional to the mass of analyte to the power 2/3. On the basis of recent observations of density affecting CAD response, this needs to be revised. The CAD response should actually be proportional to the mass of analyte divided by its density to the power 2/3. …”
Section: Resultsmentioning
confidence: 99%
“…It has previously been observed that CAD shows a decreased response for highly dense compounds and an increased response for basic compounds that ion pair with acidic species in the mobile phase. , This study has successfully tested a methodology that incorporates density and basic p K a data (available through JChem) to correct for this variable response.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…and found response factors that were all within twenty to thirty percent of each other. Recently, Matsuyama et al [106] studied brominated flame-retardants with a wide range of densities and found that CAD response varied with the density of the analyte and was proportional to the (−2/3) power of that density. These and other studies indicate that although response factors may be similar for many compounds with CAD, they may not be identical, and these variations most likely result from differences in particle density, hygroscopicity, volatility/sublimation, etc.…”
Section: Analyte Chemical Characteristicsmentioning
confidence: 99%