2017
DOI: 10.1590/1678-7757-2016-0561
|View full text |Cite
|
Sign up to set email alerts
|

Effects of continual intermittent administration of parathyroid hormone on implant stability in the presence of osteoporosis: an in vivo study using resonance frequency analysis in a rabbit model

Abstract: Objective:This study aimed to evaluate the effects of continual intermittent administration of parathyroid hormone (PTH) on implant stability in the presence of osteoporosis, using rabbit models.Material and Methods:Fifteen female New Zealand white rabbits underwent ovariectomy and were administered glucocorticoids to induce osteoporosis, following which they were divided into three groups. The first group received intermittent subcutaneous PTH for 4 weeks until implant placement (PTH1), while the second and t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0
3

Year Published

2018
2018
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(21 citation statements)
references
References 29 publications
1
17
0
3
Order By: Relevance
“…The RT reflects a quantitative assessment of osseointegration of the entire implant. RT is strongly influenced by cortical bone integration and is strongly correlated with the BIC ratio [31][32][33]. According to the BIC and The RT measurements, the alkali group obtained excellent implant stability by achieving favorable osteointegration in the cortical bone portion.…”
Section: Discussionmentioning
confidence: 99%
“…The RT reflects a quantitative assessment of osseointegration of the entire implant. RT is strongly influenced by cortical bone integration and is strongly correlated with the BIC ratio [31][32][33]. According to the BIC and The RT measurements, the alkali group obtained excellent implant stability by achieving favorable osteointegration in the cortical bone portion.…”
Section: Discussionmentioning
confidence: 99%
“…Several studies have therefore aimed to improve depreciated bone mass and bone quality using PTH administration 16,17 . PTH increases bone mass and improves its structural characteristics, and is expected to increase the availability of dental implant treatment and enable stable osseointegration after dental implant surgery 16,17 . However, the effect of PTH administration on the material characteristics of newly formed bone in the jaw is currently unclear.…”
Section: Introductionmentioning
confidence: 99%
“…Oki et al investigated the effects of continual intermittent influence of PTH on dental implant stability in the presence of osteoporosis, using rabbit models and creating artificial osteoporosis with the use of PTH in different forms before and after implantation. 15 The authors measured the implant stability coefficient immediately and after 2 and 4 weeks. According to a histological study, the quality and quantity of bone around dental implants were better in the groups of animals with adequate compensating therapy for osteoporosis.…”
Section: Figurementioning
confidence: 99%