Effects of ceiling exhaust location on thermal comfort and age of air in room under impinging jet supply scheme

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
19
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(20 citation statements)
references
References 31 publications
1
19
0
Order By: Relevance
“…In this work, these scenarios were used in cases (1) and (2), while the worst scenarios are when supply and return are on the same side. This work yields the same results as (Qin and Lu, 2021), who demonstrate that installing a ceiling exhaust diffuser in the center increases air age and improves heat removal efficiency (Qin and Lu, 2021). The results were also compared with (Shokrollahi et al, 2020) by comparing temperature distribution throughout the middle room height; both studies produced a matching velocity profile.…”
Section: Resultssupporting
confidence: 54%
See 1 more Smart Citation
“…In this work, these scenarios were used in cases (1) and (2), while the worst scenarios are when supply and return are on the same side. This work yields the same results as (Qin and Lu, 2021), who demonstrate that installing a ceiling exhaust diffuser in the center increases air age and improves heat removal efficiency (Qin and Lu, 2021). The results were also compared with (Shokrollahi et al, 2020) by comparing temperature distribution throughout the middle room height; both studies produced a matching velocity profile.…”
Section: Resultssupporting
confidence: 54%
“…CFD is being used to optimize the mean age of air and thermal comfort. The results showed that locating the ceiling exhaust in the center has a longer age of air and locating the ceiling exhaust near a thermal source will improve heat removal efficiency (Qin and Lu, 2021).…”
Section: Introductionmentioning
confidence: 99%
“…The smaller the value of τ P , the stronger the ability to remove pollutants [ 40 ]. The transport equation for τ P is written as [ 41 ]: where Sc τ denotes the turbulent Schmidt number. In this study, the value of Sc τ was set to 0.7.…”
Section: Methodsmentioning
confidence: 99%
“…The cumulative distribution function F(τ) refers to the proportion of air micro-particles with an AoA of younger than τ. τ p is a passive scalar and governed by the equation [2]:…”
Section: Aoamentioning
confidence: 99%
“…Their indoor thermal comfort directly affects their business and urban tourism [1]. Both thermal comfort and IAQ are beneficial to human health [2], since people spend almost 90% of their time indoors at present [3]. A thermal discomfort or poor IAQ environment reduces the productivity of dwellers and even their wellbeing [4].…”
Section: Introductionmentioning
confidence: 99%