Effects of body postures on the shear modulus of thoracolumbar fascia: a shear wave elastography study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
3

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 30 publications
0
12
3
Order By: Relevance
“…The present TLF SWE modulus values at rest were much lower than those reported in a series of studies by Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022) (~40 kPa). This is because we did not multiply the shear-wave velocity by a factor of 3, while Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 used the values obtained by the device. Further, Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 quantified stiffness by placing the probe axially relative to the long axis of the body, whereas we acquired images in the longitudinal orientation with the probe along the long axis of the body.…”
Section: Discussioncontrasting
confidence: 91%
See 2 more Smart Citations
“…The present TLF SWE modulus values at rest were much lower than those reported in a series of studies by Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022) (~40 kPa). This is because we did not multiply the shear-wave velocity by a factor of 3, while Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 used the values obtained by the device. Further, Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 quantified stiffness by placing the probe axially relative to the long axis of the body, whereas we acquired images in the longitudinal orientation with the probe along the long axis of the body.…”
Section: Discussioncontrasting
confidence: 91%
“…Very few studies report SWE modulus values of the TLF in healthy individuals (Chen et al, 2020(Chen et al, , 2021(Chen et al, , 2022. The present TLF SWE modulus values at rest were much lower than those reported in a series of studies by Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022) (~40 kPa). This is because we did not multiply the shear-wave velocity by a factor of 3, while Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 used the values obtained by the device.…”
Section: Discussioncontrasting
confidence: 81%
See 1 more Smart Citation
“…SWE quantifies tissue stiffness and draws a colored image of tissue stiffness using shear wave generated by acoustic radiation force pulse and ultra-high speed imaging technology (Creze et al, 2018;Gennisson et al, 2013). Our previous research shows that SWE is a reliable tool for quantifying TLF, MG, and LG stiffness and monitoring its dynamic changes (Chen et al, 2021;Liu et al, 2020). Therefore, we used SWE to quantify the stiffness of TLF, ES, and gastrocnemius during isometric plantarflexion in this experiment.…”
Section: Introductionmentioning
confidence: 99%
“…Similarly, the thoracolumbar fascia is believed to be an important stabilizer of the spine [7,8]. By surrounding the erector spinae, it is hypothesized to provide an additional hydrostatic stabilizing effect [9][10][11].…”
Section: Introductionmentioning
confidence: 99%