Effects of Isometric Plantar-Flexion on the Lower Limb Muscle and Lumbar Tissue Stiffness

Abstract: Purpose: This study investigated the effects of isometric plantar-flexion against different resistances on the thoracolumbar fascia (TLF), erector spinae (ES), and gastrocnemius stiffness by shear wave elastography (SWE). The purpose was to explore the interaction between the lower limb muscle and lumbar tissue in the myofascial tensegrity network.Methods: Twenty healthy young female were recruited in this study. The stiffness of the TLF, ES, medial gastrocnemius (MG), and lateral gastrocnemius (LG) was measur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 31 publications
0
7
3
Order By: Relevance
“…The present TLF SWE modulus values at rest were much lower than those reported in a series of studies by Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022) (~40 kPa). This is because we did not multiply the shear-wave velocity by a factor of 3, while Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 used the values obtained by the device. Further, Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 quantified stiffness by placing the probe axially relative to the long axis of the body, whereas we acquired images in the longitudinal orientation with the probe along the long axis of the body.…”
Section: Discussioncontrasting
confidence: 91%
See 3 more Smart Citations
“…The present TLF SWE modulus values at rest were much lower than those reported in a series of studies by Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022) (~40 kPa). This is because we did not multiply the shear-wave velocity by a factor of 3, while Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 used the values obtained by the device. Further, Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 quantified stiffness by placing the probe axially relative to the long axis of the body, whereas we acquired images in the longitudinal orientation with the probe along the long axis of the body.…”
Section: Discussioncontrasting
confidence: 91%
“…Very few studies report SWE modulus values of the TLF in healthy individuals (Chen et al, 2020(Chen et al, , 2021(Chen et al, , 2022. The present TLF SWE modulus values at rest were much lower than those reported in a series of studies by Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022) (~40 kPa). This is because we did not multiply the shear-wave velocity by a factor of 3, while Chen et al (2020Chen et al ( , 2021Chen et al ( , 2022 used the values obtained by the device.…”
Section: Discussioncontrasting
confidence: 80%
See 2 more Smart Citations
“…A effect size of 3.69 was calculated by the sample size calculator G∗Power 3.1.9.2, alongside a power of 95% and a significance level of 0.05. The experience of our previous study has also been taken into account (n = 20; Chen et al, 2022 ).…”
Section: Methodsmentioning
confidence: 99%