Effects of air exchange rate, particle size and injection place on particle concentrations within a reduced-scale room

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
28
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(29 citation statements)
references
References 38 publications
0
28
0
1
Order By: Relevance
“…The recommended minimum value of ACH is very similar in UNE 100713 and ASHRAE Standard 170, however, this parameter is not specified in EN 16244-2. On the one hand, increasing the amount of fresh air impelled improves dilution effectiveness [53] but, on the other hand, it does not guarantee an SSI rate decrease and, nevertheless, operating costs are always raised [54]. Infection hazard is reduced by controlling air movement pattern [52,55] which leads to an equipment expenditure and operating costs reduction.…”
Section: Discussionmentioning
confidence: 99%
“…The recommended minimum value of ACH is very similar in UNE 100713 and ASHRAE Standard 170, however, this parameter is not specified in EN 16244-2. On the one hand, increasing the amount of fresh air impelled improves dilution effectiveness [53] but, on the other hand, it does not guarantee an SSI rate decrease and, nevertheless, operating costs are always raised [54]. Infection hazard is reduced by controlling air movement pattern [52,55] which leads to an equipment expenditure and operating costs reduction.…”
Section: Discussionmentioning
confidence: 99%
“…In the engineering field, the airborne transmission between occupants indoors is usually investigated using both experiments and Computational fluid dynamics (CFD) methods [ 20 ]. Experimental methods include quantitative measurement of the concentration field [ 21 , 22 ] and imaging visualization of expiratory flows [ 11 , 12 ]. Chamber experiments using breathing thermal manikins and ancillary machines [ 23 , 24 ] have been the primary method of investigating airborne transmission between occupants and quantifying the risk of cross-infection.…”
Section: Introductionmentioning
confidence: 99%
“…Faulkner vd. [8,9] • Genel karakter olarak, artan HDK değeri ile ortalama konsantrasyon miktarı azalsa da azalma oranı ana akış bölgesi içerisinde yer alan kirletici durumunda sınırlı bir seviyede kalmakta diğer bölgelerde yer alan kirletici kaynakları durumunda ise daha belirgin olmaktadır.…”
Section: Gi̇ri̇ş (Introduction)unclassified